2012
DOI: 10.1109/tmag.2011.2172195
|View full text |Cite
|
Sign up to set email alerts
|

High Efficiency FEM Calculation of the Ionized Field Under HVDC Transmission Lines

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 31 publications
(16 citation statements)
references
References 10 publications
0
16
0
Order By: Relevance
“…in [7], [8]. In recent years, further improvements to the stability and efficiency of numerical calculation methods have been proposed in a number of publications, including [9], [10]. In [11], the validity of the Deutsch assumption was investigated with the conclusion that for high corona intensities it can lead to significant errors.…”
Section: A Bipolar Coronamentioning
confidence: 99%
“…in [7], [8]. In recent years, further improvements to the stability and efficiency of numerical calculation methods have been proposed in a number of publications, including [9], [10]. In [11], the validity of the Deutsch assumption was investigated with the conclusion that for high corona intensities it can lead to significant errors.…”
Section: A Bipolar Coronamentioning
confidence: 99%
“…The typical triangle meshes (elements) are used as shown in Fig 1. The solution of Equation (1) is equal to minimize the following function [14]:…”
Section: Solution Of Poisson's Equationmentioning
confidence: 99%
“…Previous studies [14][15][16][17][18] proposed numerical methods using FEM and FVM to calculate the ion flow under a high-voltage current transmission line. Yin [19] combines FVM with a time step to simulate the formation process of the ion-flow field of the ±800 kV HVDC test line.…”
Section: Introductionmentioning
confidence: 99%
“…Thus, the impact of haze weather on ion flow field around the HVDC transmission line is considered in this paper. Reference [7] proposed a calculation method of ion flow field which simplified the two dimensions problem into one dimension with noteworthy errors; A grid like ion flow field calculation method is proposed in reference [8], which reduces the error; Then there are upwind finite element method [9], meshless method [10] and various improved methods [11][12], which have significantly improved the accuracy. The above method can effectively calculate the ion flow field under normal weather, but weak in the calculation under complex meteorological conditions.…”
Section: Introductionmentioning
confidence: 99%