2014
DOI: 10.7785/tcrt.2012.500441
|View full text |Cite
|
Sign up to set email alerts
|

High-dose-rate Three-dimensional Conformal Radiotherapy Combined with Active Breathing Control for Stereotactic Body Radiotherapy of Early-stage Non-small-cell Lung Cancer

Abstract: The purpose of this study was to evaluate the feasibility and benefits of using high-dose-rate three-dimensional conformal radiotherapy (3D-CRT) combined with active breathing control

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 34 publications
0
2
0
Order By: Relevance
“…Radiotherapy with ABC has been performed in our hospital for nearly 15 years. Although the ABC device plays an important role in dose escalation for tumors and dose decreases for OARs 8 , 9 , 27 , there are some details that should be given special consideration. Patients should be provided with sufficient time to rest; radiation therapist should choose the right moments to stop rest and start beam-on treatment; the normal shape of the connection pipe should be maintained; the connection pipe should be kept clean and dry (especially the filter); and the tightness of the pipeline should be checked and confirmed 8 , 9 .…”
Section: Discussionmentioning
confidence: 99%
“…Radiotherapy with ABC has been performed in our hospital for nearly 15 years. Although the ABC device plays an important role in dose escalation for tumors and dose decreases for OARs 8 , 9 , 27 , there are some details that should be given special consideration. Patients should be provided with sufficient time to rest; radiation therapist should choose the right moments to stop rest and start beam-on treatment; the normal shape of the connection pipe should be maintained; the connection pipe should be kept clean and dry (especially the filter); and the tightness of the pipeline should be checked and confirmed 8 , 9 .…”
Section: Discussionmentioning
confidence: 99%
“…The 48 patients enrolled underwent a planning CT thorax scan (thoracic inlet to below the diaphragm) with intravenous contrast as clinically indicated. The scan was performed in breath-hold with the use of the an active breathing control (ABC) device, 24 or a four-dimensional (4D) scan was acquired in free-breathing if the ABC device was not tolerated. Within a 4 h period, the patient underwent a lung SPECT perfusion scan.…”
Section: Methodsmentioning
confidence: 99%