Leibel and Phillips Textbook of Radiation Oncology 2010
DOI: 10.1016/b978-1-4160-5897-7.00015-9
|View full text |Cite
|
Sign up to set email alerts
|

High Dose Rate Brachytherapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(1 citation statement)
references
References 273 publications
0
1
0
Order By: Relevance
“…The surgeon is occasionally involved in these procedures, particularly if laparotomy or craniotomy is necessary for insertion of the applicators or if tumor resection is required prior to applicator insertion. The specialist should always be aware of the indications for brachytherapy and the associated techniques [1–3]. Brachytherapy with modern afterloading equipment offers three major advantages over interstitial or intracavitary insertion of separate needles, tubes, seeds or wires: 1) isodose volumes in tissues can be created flexibly by a combination of careful placement of the catheter and adjustment of the dwell times of computerized stepping source; this process is usually called “dose optimization”, 2) automatic removal of the radiation sources into a shielded safe whenever somebody enters the procedure room eliminates radiation exposures to staff and visitors, 3) radiation exposure is also eliminated to the staff who formerly loaded and unloaded multiplicity of radioactive sources into the catheters, ovoids, tubes, etc.…”
Section: Purposementioning
confidence: 99%
“…The surgeon is occasionally involved in these procedures, particularly if laparotomy or craniotomy is necessary for insertion of the applicators or if tumor resection is required prior to applicator insertion. The specialist should always be aware of the indications for brachytherapy and the associated techniques [1–3]. Brachytherapy with modern afterloading equipment offers three major advantages over interstitial or intracavitary insertion of separate needles, tubes, seeds or wires: 1) isodose volumes in tissues can be created flexibly by a combination of careful placement of the catheter and adjustment of the dwell times of computerized stepping source; this process is usually called “dose optimization”, 2) automatic removal of the radiation sources into a shielded safe whenever somebody enters the procedure room eliminates radiation exposures to staff and visitors, 3) radiation exposure is also eliminated to the staff who formerly loaded and unloaded multiplicity of radioactive sources into the catheters, ovoids, tubes, etc.…”
Section: Purposementioning
confidence: 99%