2007 IEEE 34th International Conference on Plasma Science (ICOPS) 2007
DOI: 10.1109/ppps.2007.4345550
|View full text |Cite
|
Sign up to set email alerts
|

High Current Linear Transformer Driver (LTD) Experiments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
5
0

Year Published

2007
2007
2015
2015

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 3 publications
0
5
0
Order By: Relevance
“…The lowest breakdown field is 173 kV/mm for n=7 insulator with a covering factor of 90%. Figure 8 shows the average breakdown field with error bars for 50% (n=5, 7,8,9,10), 70% (n=3, 4,5,8), 80% (n=3 to 6) and 90% (n=5, 7,8) in comparison with those for 100% coverage and n=1, 2, 3, 4, 5, 7, 10.…”
Section: % To 100% Covering Factorsmentioning
confidence: 99%
See 2 more Smart Citations
“…The lowest breakdown field is 173 kV/mm for n=7 insulator with a covering factor of 90%. Figure 8 shows the average breakdown field with error bars for 50% (n=5, 7,8,9,10), 70% (n=3, 4,5,8), 80% (n=3 to 6) and 90% (n=5, 7,8) in comparison with those for 100% coverage and n=1, 2, 3, 4, 5, 7, 10.…”
Section: % To 100% Covering Factorsmentioning
confidence: 99%
“…Later in the 1990's and the first decade of this century, further creative developments, various research work and applications of the 0.1 to 1 s wave-front LTD have been accomplished by laboratories and institutes around the world [7][8][9][10][11][12][13]. In some LTD's, a long (5 m) bushing-like flexible insulator was employed for the secondary-turn conductor which sustained a s-time-scale impulse up to a field of above 1 MV/cm.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The LTD architecture discussed in this report was developed at the Institute of High Current Electronics (HCEI) in Tomsk, Russia. Individual LTD cavities have been tested with 10 [7,8], 16 [9,10], 20 [11], and 40 [12,13] parallel bricks. Repetitive testing of a single, high current, 20-brick cavity has been performed at Sandia to investigate lifetime of the LTD components.…”
Section: Introductionmentioning
confidence: 99%
“…The LTD adder consists of seven series cavities containing 10 parallel bricks each [14,15,8]. A high current adder was recently tested at HCEI with five series cavities with 40 parallel bricks each [13]. This high current system is being upgraded to 10 series cavities and will be tested at Sandia beginning next year.…”
Section: Introductionmentioning
confidence: 99%