2010
DOI: 10.1021/ac102159d
|View full text |Cite
|
Sign up to set email alerts
|

High Capacity Capillary Electrophoresis-Electrospray Ionization Mass Spectrometry: Coupling a Porous Sheathless Interface with Transient-Isotachophoresis

Abstract: A sheathless interface making use of a porous tip has been used for coupling capillary electrophoresis and electrospray ionization mass spectrometry. First, effective flow rates using the interface have been characterized. It was found that the interface is capable of generating a stable spray with flow rates ranging from below 10 nL/min to >340 nL/min, enabling its use in either the mass or concentration-sensitive region of the electrospray process. Subsequently, by analyzing peptide mixtures of increasing co… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

7
195
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
3
2
2

Relationship

1
6

Authors

Journals

citations
Cited by 156 publications
(202 citation statements)
references
References 29 publications
7
195
0
Order By: Relevance
“…Generally, sensitivity increases with decreasing flow rates. For example, Busnel et al obtained a 20-fold increase in sensitivity by decreasing the flow rate from 330 nl/min to 10 nl/min (40). Another advantage of minimal flow rates below 20 nl/min is the operation in the mass sensitive range of the ESI process, resulting in significantly reduced analyte suppression and improved sensitivity (55,56).…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Generally, sensitivity increases with decreasing flow rates. For example, Busnel et al obtained a 20-fold increase in sensitivity by decreasing the flow rate from 330 nl/min to 10 nl/min (40). Another advantage of minimal flow rates below 20 nl/min is the operation in the mass sensitive range of the ESI process, resulting in significantly reduced analyte suppression and improved sensitivity (55,56).…”
Section: Discussionmentioning
confidence: 99%
“…5A). In order to increase the mass loading of the system, transient isotachophoresis was integrated as an in-capillary pre-concentration procedure (40). However, applying 10 times more sample (3 pmol) did not result in any further increase in the number of peptide identifications (data not shown).…”
Section: Fig 3 Base Peak Chromatograms Of Rat Testis H1 Histones DImentioning
confidence: 98%
See 2 more Smart Citations
“…In the last two decades, it has also been demonstrated in various studies that its combination with MS provides a very powerful analytical platform for the characterization of peptides and/or protein mixtures [1,2].…”
Section: Introductionmentioning
confidence: 99%