2016
DOI: 10.1364/oe.24.016530
|View full text |Cite
|
Sign up to set email alerts
|

High-accuracy simultaneous measurement of particle size and location using interferometric out-of-focus imaging

Abstract: A method based on unidirectional gradient-matched algorithm and Fourier transform technique is proposed to simultaneously extract the location and the number of fringes/fringe spacing of a particle interferogram. The position coordinate (x,y) of a particle can be determined with high accuracy because of the elimination of the fringe within the particle fringe pattern. Furthermore, the method can be employed to achieve sub-pixel frequency extraction when combined with an improved Rife algorithm. The performance… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(4 citation statements)
references
References 20 publications
0
4
0
Order By: Relevance
“…The analysis of interferograms requires methods covering the case of interferograms of single particles to the more complex case of overlapping interferograms of closed particles. We see that the IPI technique can be used in an extreme environment where the wind speed can reach 70 m/s by following the same procedure as for IPI measurements in conventional environments [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15][16][17][18][19]. Thus, the IPI technique seems usable for carrying out airborne measurements.…”
Section: Discussionmentioning
confidence: 99%
“…The analysis of interferograms requires methods covering the case of interferograms of single particles to the more complex case of overlapping interferograms of closed particles. We see that the IPI technique can be used in an extreme environment where the wind speed can reach 70 m/s by following the same procedure as for IPI measurements in conventional environments [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15][16][17][18][19]. Thus, the IPI technique seems usable for carrying out airborne measurements.…”
Section: Discussionmentioning
confidence: 99%
“…ILIDS was performed to measure the droplets diameter, similar to that done by Qieni et al. (2016), Bocanegra Evans et al. (2015) and Garcia-Magarino et al.…”
Section: Experimental Methodologymentioning
confidence: 99%
“…ILIDS was performed to measure the droplets diameter, similar to that done by Qieni et al (2016), Bocanegra Evans et al (2015 and Garcia-Magarino et al (2021). In ILIDS, the droplet diameter is measured by analysing the interference pattern of the reflected and first-order refracted rays scattered from spherical droplets that are illuminated by a laser.…”
Section: Interferometric Laser Imaging For Droplet Sizingmentioning
confidence: 99%
“…Maas [16] was one of the first to propose an automatic PTV algorithm. To track droplets, classical PTV algorithms perform two steps [17]: droplets are detected on each image, and the trajectories are reconstructed from the detected droplets. Even in more recent work, this structure is retained [18,19].…”
Section: Introductionmentioning
confidence: 99%