2005
DOI: 10.1117/1.1829097
|View full text |Cite
|
Sign up to set email alerts
|

High-accuracy optical power measurements by using electrical-substitution cryogenic radiometer

Abstract: An optical power scale is established at Ulusal Metroloji Enstitü sü (UME) using the helium-cooled primary-level electricalsubstitution cryogenic radiometer. The scale is established at discrete laser wavelengths of vertically polarized tuneable Ar ϩ , fixed He-Ne, and Nd:YAG (with second harmonic) laser sources. To increase measurement accuracy, laser intensities are stabilized to better than 0.009% using an electro-optical modulator. The spatial profiles of polarized laser beams are cleaned with a spatial fi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2005
2005
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 20 publications
(19 reference statements)
0
6
0
Order By: Relevance
“…The detailed descriptions of these measurements are given in our previous work [10]. Following the optical power measurements responsivities of optical detection element of filter radiometer were determined by measuring its current response to the measured optical power.…”
Section: Characterization Of Optical Detection Element Of Filter Radimentioning
confidence: 99%
“…The detailed descriptions of these measurements are given in our previous work [10]. Following the optical power measurements responsivities of optical detection element of filter radiometer were determined by measuring its current response to the measured optical power.…”
Section: Characterization Of Optical Detection Element Of Filter Radimentioning
confidence: 99%
“…Intensity stabilized and vertically polarized lasers (He-Ne, Ar + and Nd:YAG) are used for the realization of the scale [5,6]. Lasers are placed on computer-controlled and motorized linear translation stage, which enables each laser beam to send into the measurement setup sequentially.…”
Section: Absolute Optical Power Scalementioning
confidence: 99%
“…Lasers are placed on computer-controlled and motorized linear translation stage, which enables each laser beam to send into the measurement setup sequentially. The output power of each laser then stabilized by using an electro-optics modulator technique [5]. A spatial filter is used to produce a clean Gaussian laser beam with a desired dimension.…”
Section: Absolute Optical Power Scalementioning
confidence: 99%
See 1 more Smart Citation
“…The absolute responsivity of filter-radiometer was linked to the absolute optical power measurements, which is based on helium-cooled electrical-substitution cryogenic radiometer [14]. Optical power measurements were performed at discrete laser wavelengths of vertically polarized tuneable Ar+ (488.0 and 514.5 nm wavelengths) and fixed Nd: YAG (532.0 nm wavelength) and He-Ne (632.8 nm wavelength) laser sources (beam diameters were aligned to $2 mm).…”
Section: Responsivity Measurement Of Trap Detectormentioning
confidence: 99%