2017
DOI: 10.1016/j.jqsrt.2017.06.012
|View full text |Cite
|
Sign up to set email alerts
|

High accuracy absorption coefficients for the Orbiting Carbon Observatory-2 (OCO-2) mission: Validation of updated carbon dioxide cross-sections using atmospheric spectra

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
32
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 40 publications
(40 citation statements)
references
References 54 publications
0
32
0
Order By: Relevance
“…There was about a 4% unexplained systematic offset between the measurements of Delahaye et al (2016a) and those of Sung et al (2009) in the same spectral region of 4.3 μm, although they were sharing the same rotational dependence. Sung et al (2009) data are used for spectroscopic input for the OCO-2 mission (Oyafuso et al, 2017), and therefore for consistency, the experimental results converted from (Delahaye et al, 2016a) were then divided by 0.96 before fitting. In order to make more accurate predictions for transitions involving high-rotational quanta, the calculated half-widths from were also incorporated into the fitting (only for 63 ≤ | m | ≤ 101 and m = 121) but were multiplied by a factor of 0.975 derived here to account for discrepancy between these calculations and measurements from Sung et al (2009).…”
Section: Comentioning
confidence: 99%
“…There was about a 4% unexplained systematic offset between the measurements of Delahaye et al (2016a) and those of Sung et al (2009) in the same spectral region of 4.3 μm, although they were sharing the same rotational dependence. Sung et al (2009) data are used for spectroscopic input for the OCO-2 mission (Oyafuso et al, 2017), and therefore for consistency, the experimental results converted from (Delahaye et al, 2016a) were then divided by 0.96 before fitting. In order to make more accurate predictions for transitions involving high-rotational quanta, the calculated half-widths from were also incorporated into the fitting (only for 63 ≤ | m | ≤ 101 and m = 121) but were multiplied by a factor of 0.975 derived here to account for discrepancy between these calculations and measurements from Sung et al (2009).…”
Section: Comentioning
confidence: 99%
“…[578]. These applications have concentration retrieval targets with uncertainties at the 0.25 % level or below and therefore motivate low-uncertainty laboratory measurements that incorporate advanced line profiles (eg [9,100,689] and references therein ; see also Sec. 5.1.1a).…”
Section: Accepted Manuscriptmentioning
confidence: 99%
“…Successive versions of these tables have been refined by incorporating new laboratory results and theoret-5 ical models for increasingly accurate absorption coefficients. The ABSCO version used in the B8 algorithm is ABSCO v5.0 Oyafuso et al, 2017).…”
Section: Spectroscopy-related Changesmentioning
confidence: 99%
“…This additional absorption was parameterized in order to reduce errors in retrievals with TCCON up-looking spectra. Further details can be found in and Oyafuso et al (2017).…”
Section: Spectroscopy-related Changesmentioning
confidence: 99%
See 1 more Smart Citation