2014
DOI: 10.2172/1214174
|View full text |Cite
|
Sign up to set email alerts
|

HFIR dissolution nuclear criticality analysis information

Abstract: The LTB function covers an H/X range of 90 < H < 2,800. The function was found over its range: LTB (90) = 0.993 and LTB (2,800) = 1.001. This indicates that the lowest possible LTB for these plutonium solutions is found at the lowest H:X value and is 0.993, which is higher than the LTL for uranium solutions. Therefore, an LTL of 0.990 (implies bias = 0.01) for uranium solutions over the range of applicability provided in SRNS-IM-2009-00035 is used. 2.6.3 Minimum Subcritical Margin (MSM) The biased k eff does n… Show more

Help me understand this report

This publication either has no citations yet, or we are still processing them

Set email alert for when this publication receives citations?