2016
DOI: 10.1016/j.chemgeo.2016.03.025
|View full text |Cite
|
Sign up to set email alerts
|

Hf isotope analysis of small zircon and baddeleyite grains by conventional Multi Collector-Inductively Coupled Plasma-Mass Spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
20
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(20 citation statements)
references
References 43 publications
0
20
0
Order By: Relevance
“…No systematic effects were found outside of quoted uncertainties. We finally note that D’Abzac et al ( 49 ) reported significant impact of Yb oxides on the peak-stripped 176 Hf/ 177 Hf ratios due to the changing mass fractionation exponent, β Yb . We did not observe such effects in our analytical session and believed that this difference is attributable to the different behavior of the cones ( 53 ), as D’Abzac et al ( 49 ) used the “jet” skimmer cone, whereas we used the “x” cones.…”
Section: Methodsmentioning
confidence: 67%
See 1 more Smart Citation
“…No systematic effects were found outside of quoted uncertainties. We finally note that D’Abzac et al ( 49 ) reported significant impact of Yb oxides on the peak-stripped 176 Hf/ 177 Hf ratios due to the changing mass fractionation exponent, β Yb . We did not observe such effects in our analytical session and believed that this difference is attributable to the different behavior of the cones ( 53 ), as D’Abzac et al ( 49 ) used the “jet” skimmer cone, whereas we used the “x” cones.…”
Section: Methodsmentioning
confidence: 67%
“…Analyses were made by solution of MC-ICPMS on the ThermoFinnigan Neptune at UCLA using a Cetac “Aridus II” desolvating nebulizer. Analyses were done without matrix purification following the analytical protocol of D’Abzac et al ( 49 ). Analytical parameters were summarized in table S2, and data were presented in table S3 (A and B).…”
Section: Methodsmentioning
confidence: 99%
“…The high trace element contents results in high Yb/Hf ratios (Supplementary Data 2) and for this reason, measuring the Hf isotopic composition on the washes from U-Pb chemistry63 is not possible without purification. We used a simplified cation column chemistry procedure (similar to ref.…”
Section: Methodsmentioning
confidence: 99%
“…63. The nine Faraday cups were configured to measure the following masses at low mass resolution (m/_m ∼450): 172 (L4), 173 (L3), 175 (L2), 176 (L1), 177 (C), 178 (H1), 179 (H2), 180 (H3), 181 (H4).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation