2021
DOI: 10.1002/clt2.12084
|View full text |Cite
|
Sign up to set email alerts
|

Heterogeneous validity of daily data on symptoms of seasonal allergic rhinitis recorded by patients using the e‐diary AllergyMonitor®

Abstract: Background Patient‐generated symptom and medication scores are essential for diagnostic and therapeutic decisions in seasonal allergic rhinitis (SAR). Previous studies have shown solid consistencies between different scores at population level in real‐life data and trials. For clinicians, the evaluation of individual data quality over time is essential to decide whether to rely on these data in clinical decision‐making. Objective To analyze the consistency of different symptom (SS) and symptom medication score… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 33 publications
0
8
0
Order By: Relevance
“…The strong correlation between VAS-RS with TSS 4 and TNSS indicates the concurrent validity of VAS. The correlations between RQLQ and daily PROMs were similar when considering the last study day or the median weekly values.…”
Section: Patient-reported Outcome Measures In Birch Pollen Allergic P...mentioning
confidence: 87%
“…The strong correlation between VAS-RS with TSS 4 and TNSS indicates the concurrent validity of VAS. The correlations between RQLQ and daily PROMs were similar when considering the last study day or the median weekly values.…”
Section: Patient-reported Outcome Measures In Birch Pollen Allergic P...mentioning
confidence: 87%
“…27 Major scientific organizations and research networks agree that the smartphone technology opens new avenues for disease monitoring 15,28,29 but they also alert on the need of finding consensus on their proper use, based on scientific validation of the elements composing this new diagnostic procedure. 15,30 To this end, the quantity, and the quality 31,32 of the data entered by each individual patient must be proven before the acquired information is used for clinical decisions. Once the data are validated, the clinician may wish to analyse the individual patient's trends of disease control scores, ideally via user-friendly visualizations.…”
Section: Pros Pec Tive Monitoring Of D Is E a S E Control : Are E -D ...mentioning
confidence: 99%
“…via specific VAS). 30,31 The use of these scores has been widely investigated and approved by consensus in international guidelines for clinical research. 30,35,36 From the broad spectrum of possible parameters, taken alone or combined and weighted through indices and scores, the proper choice of the most adequate ones may be difficult.…”
Section: Me a Suring D Is E A S E Control With E -D Iarie S: Whi Ch P...mentioning
confidence: 99%
See 1 more Smart Citation
“…The quality of the AllergyMonitor ® data was checked by estimating the percentage of changes in trends of the trajectories produced by the patients' data. 49 …”
Section: Validation and Main Characteristics Of Mhealth Apps In Rhino...mentioning
confidence: 99%