2021
DOI: 10.1364/ao.420044
|View full text |Cite
|
Sign up to set email alerts
|

Heterodyne photothermal spectroscopy of methane near 1651 nm inside hollow-core fiber using a bismuth-doped fiber amplifier

Abstract: We present laser-based methane detection near 1651 nm inside an antiresonant hollow-core fiber (HCF) using photothermal spectroscopy (PTS). A bismuth-doped fiber amplifier capable of delivering up to more than 160 mW at 1651 nm is used to boost the PTS signal amplitude. The design of the system is described, and the impact of various experimental parameters (such as pump source modulation frequency, modulation amplitude, and optical power) on signal amplitude and signal-to-noise ratio is analyzed. Comparison w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 14 publications
(8 citation statements)
references
References 52 publications
0
8
0
Order By: Relevance
“…When the pump power in the input SMF is ∼178 mW, the detected 2f signal of 5% CO 2 in the laboratory conditions is shown in Figure 9a. The absorption lines of 12 CO 2 R(68) and 13 CO 2 R(38) are well-defined without the interference from the absorption of H 2 O. Figure 9b shows the p.p.…”
Section: ■ Resultsmentioning
confidence: 97%
See 3 more Smart Citations
“…When the pump power in the input SMF is ∼178 mW, the detected 2f signal of 5% CO 2 in the laboratory conditions is shown in Figure 9a. The absorption lines of 12 CO 2 R(68) and 13 CO 2 R(38) are well-defined without the interference from the absorption of H 2 O. Figure 9b shows the p.p.…”
Section: ■ Resultsmentioning
confidence: 97%
“…Figure 9b shows the p.p. values of the selected line pair over a period of 1 h, where the blue dots are 12 CO 2 R(68) and the red dots are 13 CO 2 R(38). The average of the 13 CO 2 / 12 CO 2 as 13 R reference is used to calculate the DOB value, as shown by the black dots in Figure 9b.…”
Section: ■ Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The earliest application of this method for measuring low-concentrated gaseous samples was published in the early 1980s using a Mach–Zehnder interferometer [ 6 ]. To date, many additional PTS instruments have been published, with which a wide variety of gas types have been sensed down to ppb and ppt levels, e.g., nitrogen dioxide [ 7 , 8 ], carbon dioxide [ 9 ] and many others [ 10 , 11 , 12 , 13 ].…”
Section: Introductionmentioning
confidence: 99%