2002
DOI: 10.1016/s0963-9969(02)00087-x
|View full text |Cite
|
Sign up to set email alerts
|

Heterocyclic aromatic amines in cooked hamburgers and chicken obtained from local fast food outlets in the Ottawa region

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
37
1

Year Published

2005
2005
2019
2019

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 50 publications
(40 citation statements)
references
References 24 publications
2
37
1
Order By: Relevance
“…However, MeIQx content of the meatballs with and without CLA was generally similar to the values reported in the literature. Knize et al (1994) determined MeIQx at levels between nd-7.3 ng/g in beef fried at 150e230 C for 4e20 min; Klassen, Lewis, Lau, and Sen (2002) determined MeIQx levels between 0.3 and 0.34 ng/g in beef pan-fried at 160e220 C for 14 min. There are, however, other studies in which much higher MeIQx values have been identified.…”
Section: Tablementioning
confidence: 99%
“…However, MeIQx content of the meatballs with and without CLA was generally similar to the values reported in the literature. Knize et al (1994) determined MeIQx at levels between nd-7.3 ng/g in beef fried at 150e230 C for 4e20 min; Klassen, Lewis, Lau, and Sen (2002) determined MeIQx levels between 0.3 and 0.34 ng/g in beef pan-fried at 160e220 C for 14 min. There are, however, other studies in which much higher MeIQx values have been identified.…”
Section: Tablementioning
confidence: 99%
“…Earlier reports have shown low levels of HAs in meat, beef and chicken (Klassen et al, 2002, Philippe et al, 2000, Sinha et al, 1998, Skog et al, 1998. The presence of MeIQx and PhIP has been reported in meat extract (2.3 and 1.5 ng g -1 , respectively), grilled beef (16.4 and 67.5 ng g -1 , respectively) and fried chicken (1.0 and 70.0 ng g -1 , respectively) (Skog et al, 1998).…”
Section: Compounds Bias* (%) Precision(%) Compounds Bias(%) Precision(%)mentioning
confidence: 91%
“…In the last part of the study, the ammonium acetate (pH 4.0), usually employed in HAA chromatographic separation [5,7,14,17,18], was evaluated for the study of the amine retention by IPC and the results in terms of peak shape, analysis time and detectability of the analytes were compared with those obtained with the ammonium formate/formic acid buffer. The same eluent gradient as reported in Section 2 was run for both buffer solutions.…”
Section: Influence Of Buffers On the Ion-pair Chromatography Of Haas mentioning
confidence: 99%
“…As regards to HPLC, separation of HAAs is commonly performed on a reversed-phase (RP) C 18 column [5][6][7][8][9][10][11][12][13][14][15]. However, a drawback of ordinary RPLC is that organic solute ions exhibit poor peak shapes and inadequate retention.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation