2007
DOI: 10.1016/j.jconrel.2006.11.004
|View full text |Cite
|
Sign up to set email alerts
|

Heparin conjugated polymeric micelle for long-term delivery of basic fibroblast growth factor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
56
1
2

Year Published

2008
2008
2014
2014

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 86 publications
(59 citation statements)
references
References 35 publications
0
56
1
2
Order By: Relevance
“…However, the LHSA1 and LHSA3 conjugates did not possess the hydrophobicity necessary for the formation of stable nanoparticles due to the low substitution ratio of SA. Additionally, the CMC value of the LHSA5 conjugate was significantly lower (44 μg mL −1 ) than those of other lowmolecular-weight surfactants or amphiphilic polymers, 49,50 indicating that it can form stable nanoparticle structures, even in the presence of the reduced polymer concentrations after dilution with body fluids.…”
Section: Discussionmentioning
confidence: 93%
“…However, the LHSA1 and LHSA3 conjugates did not possess the hydrophobicity necessary for the formation of stable nanoparticles due to the low substitution ratio of SA. Additionally, the CMC value of the LHSA5 conjugate was significantly lower (44 μg mL −1 ) than those of other lowmolecular-weight surfactants or amphiphilic polymers, 49,50 indicating that it can form stable nanoparticle structures, even in the presence of the reduced polymer concentrations after dilution with body fluids.…”
Section: Discussionmentioning
confidence: 93%
“…Changes in anisotropy of fluorescent probes have also been associated with the onset of micellization [163,164]. Pyrene has been used by many research groups for CMC determination of the polymeric micelles; few examples include micelles formed from methoxy PEG-PCL, [165] [169], and Tetronic-PCL-heparin [170].…”
Section: Fluorescence Probementioning
confidence: 99%
“…One of the primary goals in this study was to solubilize PTX by means of hydrotropic micelles without using any organic solvent. Typical method to generate micelles and to load a poorly water-soluble drug into the micelles has used organic solvent, which might be removed by dialysis [10,30] or evaporation methods [31,32]. Even in the previous study on the hydrotropic PEG-b-P(2-VBODENA) polymer micelle, the very high loading content could be obtained via a dialysis method, but with use of acetonitrile as a solvent to dissolve PTX and the polymer.…”
Section: Property Of Paclitaxel-containing Hydrotropic Micellesmentioning
confidence: 99%