1990
DOI: 10.1016/s0022-5223(19)36952-1
|View full text |Cite
|
Sign up to set email alerts
|

Hemodynamic response to pumpless extracorporeal membrane oxygenation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

1997
1997
2017
2017

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 13 publications
0
3
0
Order By: Relevance
“…The setting of 10% of the CO as the minimum bypass flow was used based on the study by Brunston et al ( 23 ), who reported that a gradual rise in the systemic PaCO 2 was seen at flows of >500 ml/min (~7% of the CO) in healthy sheep. Again, when the blood flow exceeded 25% of the CO, vasoactive drugs are usually required ( 24 ). The results of the present study revealed that a maximum flow of 25% of the CO is recommended, as it does not cause any fluctuation of hemodynamic parameters and does not require vasopressor agent application.…”
Section: Discussionmentioning
confidence: 99%
“…The setting of 10% of the CO as the minimum bypass flow was used based on the study by Brunston et al ( 23 ), who reported that a gradual rise in the systemic PaCO 2 was seen at flows of >500 ml/min (~7% of the CO) in healthy sheep. Again, when the blood flow exceeded 25% of the CO, vasoactive drugs are usually required ( 24 ). The results of the present study revealed that a maximum flow of 25% of the CO is recommended, as it does not cause any fluctuation of hemodynamic parameters and does not require vasopressor agent application.…”
Section: Discussionmentioning
confidence: 99%
“…CHAPMAN et al [15] investigated the hemodynamic response to pump-less membrane extracorporeal oxygenation in 11 dogs induced to respiratory insufficiency by the intravenous use of oleic acid (0.01 mL/kg). The results demonstrated that there was an improvement in the gasometry, resulting in significant alterations in the peripheral vascular resistance, systemic arterial pressure and cardiac output.…”
Section: Rev Bras Cir Cardiovasc 2003; 18(4): 359-363mentioning
confidence: 99%
“…Other arteriovenous CO2 removal (AVCO2R) studies have also been accompanied by hemodynamic instability. 15 We recently developed an AVCOaR circuit with use of a new low-resistance membrane oxygenator to provide total CO 2 removal in both healthy a6 and injured 17 sheep models of severe respiratory failure. Total CO 2 removal could be achieved with significant reductions in minute ventilation and peak inspiratory pressures.…”
mentioning
confidence: 99%