Abdominal inflation with CO2 is used to facilitate laparoscopic surgeries, however providing adequate mechanical ventilation in this scenario is of major importance during anesthesia management. We characterized high frequency percussive ventilation (HFPV) in protecting from the gas exchange and respiratory mechanical impairments during capnoperitoneum. In addition, we aimed to assess the difference between conventional pressure-controlled mechanical ventilation (CMV) and HFPV modalities generating the high-frequency signal intratracheally (HFPVi) or extrathoracally (HFPVe). Anesthetized rabbits (n=16) were mechanically ventilated by random sequences of CMV, HFPVi, and HFPVe. The ventilator superimposed the conventional waveform with two high frequency signals (5 Hz and 10 Hz) during intratracheal HFPV (HFPVi) and HFPV with extrathoracic application of oscillatory signals through a sealed chest cuirass (HFPVe). Lung oxygenation index (PaO2/FiO2), arterial partial pressure of carbon dioxide (PaCO2), intrapulmonary shunt (Qs/Qt), and respiratory mechanics were assessed before abdominal inflation, during capnoperitoneum, and after abdominal deflation. Compared with CMV, HFPVi with additional 5-Hz oscillations during capnoperitoneum resulted in higher PaO2/FiO2, lower PaCO2, and decreased Qs/Qt. These improvements were smaller but remained significant during HFPVi with 10 Hz and HFPVe with either 5 or 10 Hz. The ventilation modes did not protect against capnoperitoneum-induced deteriorations in respiratory tissue mechanics. These findings suggest that high frequency oscillations combined with conventional pressure-controlled ventilation improved lung oxygenation and CO2 removal in a model of capnoperitoneum. Compared with extrathoracic pressure oscillations, intratracheal generation of oscillatory pressure bursts appeared more effective. These findings may contribute to the optimization of mechanical ventilation during laparoscopic surgery.
Abdominal inflation with CO2 is used to facilitate laparoscopic surgeries, however providing adequate mechanical ventilation in this scenario is of major importance during anesthesia management. We characterized high frequency percussive ventilation (HFPV) in protecting from the gas exchange and respiratory mechanical impairments during capnoperitoneum. In addition, we aimed to assess the difference between conventional pressure-controlled mechanical ventilation (CMV) and HFPV modalities generating the high-frequency signal intratracheally (HFPVi) or extrathoracally (HFPVe). Anesthetized rabbits (n=16) were mechanically ventilated by random sequences of CMV, HFPVi, and HFPVe. The ventilator superimposed the conventional waveform with two high frequency signals (5 Hz and 10 Hz) during intratracheal HFPV (HFPVi) and HFPV with extrathoracic application of oscillatory signals through a sealed chest cuirass (HFPVe). Lung oxygenation index (PaO2/FiO2), arterial partial pressure of carbon dioxide (PaCO2), intrapulmonary shunt (Qs/Qt), and respiratory mechanics were assessed before abdominal inflation, during capnoperitoneum, and after abdominal deflation. Compared with CMV, HFPVi with additional 5-Hz oscillations during capnoperitoneum resulted in higher PaO2/FiO2, lower PaCO2, and decreased Qs/Qt. These improvements were smaller but remained significant during HFPVi with 10 Hz and HFPVe with either 5 or 10 Hz. The ventilation modes did not protect against capnoperitoneum-induced deteriorations in respiratory tissue mechanics. These findings suggest that high frequency oscillations combined with conventional pressure-controlled ventilation improved lung oxygenation and CO2 removal in a model of capnoperitoneum. Compared with extrathoracic pressure oscillations, intratracheal generation of oscillatory pressure bursts appeared more effective. These findings may contribute to the optimization of mechanical ventilation during laparoscopic surgery.
Background Mechanical ventilation during general anesthesia may impair airway mucosal function. This study aimed to investigate the effect of pressure-controlled ventilation-volume guaranteed (PCV-VG) on bronchial mucus transport velocity (BTV) in patients during laparoscopic surgery for gynecological oncology compared with volume controlled ventilation (VCV). Methods 66 patients undergoing elective a laparoscopic surgery for gynecological oncology. The patients were randomized into two group receiving either PCV-VG or VCV. a drop of methylene blue was placed on the surface of the airway mucosa under the bronchoscopeand, then the distance the dye movement was measured after 2, 4, and 6 min. Outcomes were assessed at T0 (5 min after endotracheal intubation and before initiation of pneumoperitoneum), T1 and T2 (1 and 2 h after stabilization of pneumoperitoneum respectively). BTV at T0, T1 and T2 was the primary outcome. Secondary outcomes included heart rate (HR), mean arterial pressure (MAP), body temperature, end-tidal CO2 pressure (PETCO2), tidal volume(VT), peak inspiratory pressure (PIP), mean inspiratory pressure (Pmean), respiratory rate (RR), and dynamic compliance (CDyn) at T0, T1, and T2. Results 64 patients were included in the analysis. The median [interquartile range] BTV was significantly lower in VCV group at T1 and T2 that at T0 (P < 0.05). Furthermore, BTV was slightly reduced in PCV-VG compared with VCV. BTV in PCV-VG was significantly decreased at T2 compared with BTV at T0 (P < 0.05) and slightly decreased at T1 compared with T0(P > 0.05). Compared with the PCV-VG group, BTV in VCV group significantly decreased at T2 (P < 0.05). No participants experienced respiratory complications. Conclusions PCV-VG is more suitable for patients undergoing laparoscopic surgery for gynecological oncology than VCV since it can protect mucociliary clearance function. Trial registration This trial is registered on https://www.chictr.org.cn/ in Chinese Clinical Trial Registry (ChiCTR.2200064564: Date of registration 11/10/2022).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.