Hemocompatibility Testing of Blood-Contacting Implants in a Flow Loop Model Mimicking Human Blood Flow

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
4

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 0 publications
0
6
0
Order By: Relevance
“…In contact with heparinized blood in a Chandler loop or a ow loop model mimicking human blood ow, the coatings suppressed thrombin generation, platelets and leukocyte activation, complement activation and blood clot formation. 29,40 The results presented herein indicate that the binding of GFs preserve the excellent hemocompatibility of the Fb/Hep coating.…”
Section: Hemocompatibility Of the Coatingsmentioning
confidence: 62%
See 1 more Smart Citation
“…In contact with heparinized blood in a Chandler loop or a ow loop model mimicking human blood ow, the coatings suppressed thrombin generation, platelets and leukocyte activation, complement activation and blood clot formation. 29,40 The results presented herein indicate that the binding of GFs preserve the excellent hemocompatibility of the Fb/Hep coating.…”
Section: Hemocompatibility Of the Coatingsmentioning
confidence: 62%
“…We have previously reported on the significantly improved in vitro hemocompatibility of PVC substrates 29 and neurovascular stents 40 that had been modified with Fb/Hep coatings by a similar technique as applied here. In contact with heparinized blood in a Chandler loop or a flow loop model mimicking human blood flow, the coatings suppressed thrombin generation, platelets and leukocyte activation, complement activation and blood clot formation.…”
Section: Resultsmentioning
confidence: 99%
“…This reduction in platelet surface coverage was far greater than the amount of reduction observed for recent heparin drug-eluting stents [ 23 , 24 , 26 ], which showed far more platelet adhesion to their modified steel samples as compared to MEG-OH-coated samples, and poorer reduction in adhesion of less than 80% compared to the greater-than-90% adhesion observed for MEG-OH. Additionally, the amount of platelet reduction was greater than that observed for recent graphene surface coatings on steel which display an 80–90% reduction [ 30 , 31 , 32 ], and performed similarly to hydrogel coatings, with a greater-than-90% reduction [ 33 , 34 ].…”
Section: Resultsmentioning
confidence: 68%
“…More recent advances in drug eluting stents include heparin-eluting stents [ 22 , 23 , 24 , 25 ] and combined heparin–nitric-oxide-eluting stents [ 26 , 27 ], which elute the anti-coagulant drug heparin and anti-bacterial nitric oxide. Several different methods are used to measure the amount of platelet adhesion and thrombus formation to these coatings, but these only typically reduce thrombus formation to a level in the range of 60–80%.…”
Section: Introductionmentioning
confidence: 99%
“…In the flow loop model blood is perfused through a heparinized tubing containing the test specimen by using a peristaltic pump at a specific rate as previously described extensively [40]. First, heparin-coated (Ension, Pittsburgh, USA) PVC tubes with an inner diameter of 3.175 mm (Saint-Gobain Performance Plastics, Courbevoie, France) and a length of 75 cm were loaded with a test specimen each.…”
Section: Blood Circulation Modelsmentioning
confidence: 99%