2013
DOI: 10.1016/j.clinbiomech.2013.06.007
|View full text |Cite
|
Sign up to set email alerts
|

Height restoration and maintenance after treating unstable osteoporotic vertebral compression fractures by cement augmentation is dependent on the cement volume used

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
44
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 46 publications
(46 citation statements)
references
References 20 publications
1
44
0
Order By: Relevance
“…The latest developments in kyphoplasty include different implants that remain within the vertebra and restore the achieved reduction height temporarily until the cement is injected and hardened (Kruger et al, 2013;Rotter et al, 2010). However, none of these new procedures works without the additive use of cement (Kruger et al, 2013).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The latest developments in kyphoplasty include different implants that remain within the vertebra and restore the achieved reduction height temporarily until the cement is injected and hardened (Kruger et al, 2013;Rotter et al, 2010). However, none of these new procedures works without the additive use of cement (Kruger et al, 2013).…”
Section: Discussionmentioning
confidence: 99%
“…The augmented vertebrae were loaded by cyclic sinusoidal dynamic compression to simulate daily loads acting on the vertebra due to patient's activity. For this purpose, 10,000 cycles were performed between 200 N and 600 N with a frequency of 1 Hz (Kruger et al, 2013). Following the cyclical testing all vertebrae were examined by CT for the fourth time.…”
Section: Mechanical Testingmentioning
confidence: 99%
See 1 more Smart Citation
“…50 Other recent studies report that cement volume is of the utmost importance for correcting deformities and maintaining vertebral height. 51 Sun et al 40 recently published their experience with 43 patients with spinal metastasis and epidural compression treated with percutaneous vertebroplasty. In this report, they state that the stopping point is determined when the cement reaches the posterior quarter of the vertebral body.…”
Section: Indications and Contra-indicationsmentioning
confidence: 99%
“…Posterior fixation was accomplished with high viscosity polymethyl methacrylate (PMMA) cement (400 Pa) with zirconium oxide to improve visibility (Figure 2A-C) (26,27).…”
Section: Surgical Techniquementioning
confidence: 99%