2005
DOI: 10.1080/08916150500201560
|View full text |Cite
|
Sign up to set email alerts
|

Heat Transfers in Tubes Fitted with Single, Twin, and Triple Twisted Tapes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
30
0

Year Published

2008
2008
2021
2021

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 89 publications
(31 citation statements)
references
References 19 publications
1
30
0
Order By: Relevance
“…A comparative study of heat transfer and friction factor in the round tubes fitted with single, twin and triple twisted tapes was reported by Chang et al [8]. For their findings, the heat transfer enhancements achieved for laminar flows in the tubes fitted with single, twin and triple twisted tapes were, respectively, 1.5-2.3, 1.98-2.8 and 2.86-3.76 times of the Dittus-Boelter levels.…”
Section: Introductionmentioning
confidence: 84%
“…A comparative study of heat transfer and friction factor in the round tubes fitted with single, twin and triple twisted tapes was reported by Chang et al [8]. For their findings, the heat transfer enhancements achieved for laminar flows in the tubes fitted with single, twin and triple twisted tapes were, respectively, 1.5-2.3, 1.98-2.8 and 2.86-3.76 times of the Dittus-Boelter levels.…”
Section: Introductionmentioning
confidence: 84%
“…Methods of the PHE have been extensively explored with the attempts to overcome the thermal problems subject to high heat flux [4]. A variety of surface ribs [5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][21], perforated baffle [22][23][24][25][26][27], pin-fins [28][29][30][31][32], Snail, propeller, twisted and winglet-type vortex generators [33,34,30,[35][36][37][38][39][40][41][42][43][44][45][46] have been devised to enhance heat transfer rates in ducts. However, it is shown in the literature review that detail exploration of turned flow in the channel needs more extensive study.…”
Section: Introductionmentioning
confidence: 99%
“…Figure 6 shows the influence of O-Tri/O-Rec/O-Tra/P-Tri/P-Rec/P-Tra on the thermohydraulic performance behaviors. All thermohydraulic performances are evaluated at equivalent pumping power constraint [40][41][42]. For the tubes equipped with O-Tri/ORec/O-Tra/P-Tri/P-Rec/P-Tra, thermohydraulic performance considerably decreases as the Reynolds number increases and consistently above unity for the present Reynolds number range.…”
Section: 3mentioning