2019
DOI: 10.1007/978-3-030-11187-8_2
|View full text |Cite
|
Sign up to set email alerts
|

Heat Resistant Monitoring System for Medical Sterile Containers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
3
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
2

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 36 publications
1
3
0
Order By: Relevance
“…Therefore, the reliability of this insulation cannot be guaranteed. This conclusion was also made by a previous work [31]. Hereby, the thermal insulation of a special developed epoxy resin was evaluated.…”
Section: Thermal Insulation Materials Selectionsupporting
confidence: 60%
See 1 more Smart Citation
“…Therefore, the reliability of this insulation cannot be guaranteed. This conclusion was also made by a previous work [31]. Hereby, the thermal insulation of a special developed epoxy resin was evaluated.…”
Section: Thermal Insulation Materials Selectionsupporting
confidence: 60%
“…In the previous research it was found out that a highly efficient and low-profile encapsulation is possible, however, due to the pressure changes during steam sterilization, an outer encapsulation using epoxy resin needs to be used, protecting the fragile aerogel [31]. These results were carried out in this work.…”
Section: Thermal Insulation Materials Selectionmentioning
confidence: 97%
“…In order to provide better protection for the electronics, the heat transfer must be reduced. Therefore, the current issues of the state of the art, described by Böhler et al and George and Barrett [ 13 , 14 ], for reliable encapsulate electronics for the use in autoclaves need to be further investigated. The experimental results also show that the core temperature of the sensor system reaches 116 .…”
Section: Discussionmentioning
confidence: 99%
“…Research showed that, during the encapsulation process, air encapsulations cause severe damage during the sterilization-in particular, using a nonflexible epoxy resin that requires a complex setup. The issue, in this case, is that failures often occur after a multitude of sterilizations, causing unexpected damage in the system as shown in previous works by Böhler et al and George and Barrett [13,14]. In addition to the protection of the electronics from high temperatures, a long runtime has to be ensured.…”
Section: State Of the Art For Sterilization Process Validationmentioning
confidence: 99%