2014 IEEE Conference and Expo Transportation Electrification Asia-Pacific (ITEC Asia-Pacific) 2014
DOI: 10.1109/itec-ap.2014.6940980
View full text | Cite
|
Sign up to set email alerts
|

Abstract: In this paper, we tested the heat dissipating performance of a self-developed 2 in 1 direct cooling IGBT module and contrasted with the traditional indirect cooling module, and a simulation model for the module was verified accurate. The experiment results show that entire thermal resistance of the direct cooling module is reduced up to 33%, meanwhile the temperature field distribution is more uniform. Then we conducted the heat dissipation structure design for a high power density inverter, and got a satisfac… Show more

Help me understand this report

This publication either has no citations yet, or we are still processing them

Set email alert for when this publication receives citations?

See others like this or search for similar articles