2021
DOI: 10.1109/jstqe.2020.3002084
|View full text |Cite
|
Sign up to set email alerts
|

Heart-Rate Monitoring With an Ethyl Alpha-Cyanoacrylate Based Fiber Fabry-Perot Sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(12 citation statements)
references
References 37 publications
0
12
0
Order By: Relevance
“…The advantage of use of optical recording for detection of phases of heart activity in the MRI environment is that the optical instrumentation has high immunity to the artifacts caused by both magnetic and high-frequency electromagnetic fields. Today, the most commonly used types of optical sensors include sensors based on the light interference [39], [40], and Fiber Bragg Grating (FBG) sensors that evaluate changes of light reflected on a grating structure [41]- [44]. The other currently developed type of optical sensor is based on the principle of measuring changes in light output caused by bends of optical fiber [45], [46].…”
Section: B Recent Approaches To Mr Triggeringmentioning
confidence: 99%
“…The advantage of use of optical recording for detection of phases of heart activity in the MRI environment is that the optical instrumentation has high immunity to the artifacts caused by both magnetic and high-frequency electromagnetic fields. Today, the most commonly used types of optical sensors include sensors based on the light interference [39], [40], and Fiber Bragg Grating (FBG) sensors that evaluate changes of light reflected on a grating structure [41]- [44]. The other currently developed type of optical sensor is based on the principle of measuring changes in light output caused by bends of optical fiber [45], [46].…”
Section: B Recent Approaches To Mr Triggeringmentioning
confidence: 99%
“…The output is demodulated by fringe counting, and HR and pulse pressure information are obtained simultaneously through fringe pattern analysis and Kirchhoff-Love's plate theory, respectively. Y. Li et al introduced an FFPI based on ethyl alpha-cyanoacrylate (EtCNA) for HR monitoring [23]. The FFPI is fixed in the capillary tube by using an EtCNA binder.…”
Section: Optical Fiber Fabry-perot Interferometersmentioning
confidence: 99%
“…The FOS for heart monitoring can be placed under a mat [12,13,35,36] or a mattress [14,[18][19][20]38,39]. Some researchers have also made wearable sensors that can be attached to the body [37] or worn on the wrist [21][22][23]. Sensors used for body temperature monitoring need to be in direct contact with the skin, such as on an arm, in order to measure accurate results [4,5].…”
Section: Application Of Vital Signs Monitoringmentioning
confidence: 99%
See 1 more Smart Citation
“…In contrast, optical-fiber sensors are not susceptible to electromagnetic interferences, have good insulation, are thin, exhibit high resolutions, allow long-distance transmissions, and can be easily reused. Hence, in the past few decades, they have been widely investigated and used in structural health, industrial, aerospace architecture, medical, and environmental monitoring [ 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 , 9 ]. Moreover, optical-fiber sensing technology has been used for acoustic signal detection in various fields as well [ 2 , 8 , 10 , 11 , 12 , 13 , 14 ].…”
Section: Introductionmentioning
confidence: 99%