1928
DOI: 10.1080/00221309.1928.9920128
|View full text |Cite
|
Sign up to set email alerts
|

“Hearing” with the Sense of Touch

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
30
1

Year Published

1930
1930
2016
2016

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 96 publications
(32 citation statements)
references
References 0 publications
1
30
1
Order By: Relevance
“…It is significant that in the published research on vibrotactile intensity discrimination, the lowest relative DLs for the detection of changes in vibration amplitude have been reported in a study in which an amplitude-modulation method was used (Knudson, 1928), a method similar to the continuous-pedestal condition. At low amplitudes of stimulation, the relative DL was approximately 1.0 dB, and, as amplitude was increased, the relative DL decreased, eventually approaching values as low as 0.4 dB.…”
Section: A Methodsmentioning
confidence: 97%
See 1 more Smart Citation
“…It is significant that in the published research on vibrotactile intensity discrimination, the lowest relative DLs for the detection of changes in vibration amplitude have been reported in a study in which an amplitude-modulation method was used (Knudson, 1928), a method similar to the continuous-pedestal condition. At low amplitudes of stimulation, the relative DL was approximately 1.0 dB, and, as amplitude was increased, the relative DL decreased, eventually approaching values as low as 0.4 dB.…”
Section: A Methodsmentioning
confidence: 97%
“…The Weber constant c, the ratio between DL and stimulus intensity, however, has been found to be somewhat variable from experiment to experiment. Knudson (1928) reported the lowest value (0.05), a value corresponding to a 0.4-dB increase in amplitude, and Sherrick (1950) reported the highest value (0.3 as cited by Craig, 1972), corresponding to a 2.3-dB increase in amplitude. Weber constants between these extremes have been reported by Craig ( 1972Craig ( , 1974, Fucci et aT.…”
Section: Introductionmentioning
confidence: 89%
“…The same psychophysical algorithm described above was used, with stimulus adjustments of 4 units (lo-' amperes). 'This algorithm differs from that suggested by the manufacturer only in that we have specified the target number of trials (at least 20) within which a minimum target number of stimulus intensity adjustment direction changes (at least 4) must have occurred. We also required that two consecutively correct trials have occurred before lowering the intensity.…”
Section: Subjectsmentioning
confidence: 97%
“…A contactor which ( u ) is capable of application not only to the finger tips, the area most commonly selected, but also to the less accessible areas of the skin or (6) with which the more easily manipulated areas can be brought into contact. It is desirable that contact mediums of different sizes be provided for the investigation of skin areas of correspondingly different size.…”
mentioning
confidence: 99%