2018
DOI: 10.13005/bpj/1537
|View full text |Cite
|
Sign up to set email alerts
|

Healthcare Monitoring System Based on Wireless Sensor Network for Cardiac Patients

Abstract: Cardiovascular diseases (CVD) are the major cause of mortality globally, as well as in India. Most of the deaths caused by CVD are sudden and without giving any chance to provide any medical help. To avoid such impulsive accidental deaths precautions are always required. Due to this heart patients require continuous monitoring of certain vital body parameters such as heart rate, pulse rate and electrocardiogram (ECG) showing current health status clearly. In this paper we are presenting 3 - tier architecture … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
24
0
1

Year Published

2020
2020
2022
2022

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 39 publications
(29 citation statements)
references
References 13 publications
0
24
0
1
Order By: Relevance
“…Moreover, we have ( , , 2 ) from HN to FN that results in = 224 + 224 + 32 = 480 bit. Those results demonstrate that our system has the least overhead in a GW side more than all schemes in the comparison [16,17,19,22], with more strength versus numerous attacks, as shown in Table 8.…”
Section: Methodsmentioning
confidence: 52%
See 3 more Smart Citations
“…Moreover, we have ( , , 2 ) from HN to FN that results in = 224 + 224 + 32 = 480 bit. Those results demonstrate that our system has the least overhead in a GW side more than all schemes in the comparison [16,17,19,22], with more strength versus numerous attacks, as shown in Table 8.…”
Section: Methodsmentioning
confidence: 52%
“…The computational cost of the proposed scheme is better than all other schemes in the foreign network side by 60% and 65% and HN side [17,19,22] with a 80% by using P-I and 85% by using P-II. Besides, P-I and P-II perform better than [12,16] in the foreign network side along with HN side with 5% and 15% reduction, respectively, as depicted in Figures 16 and 17. Furthermore, we chose a hash function with a 224 bit key size to allow the foreign network to have an adequate level of security better than [12] which takes a 160 bit key size, and [19,22] which takes a 128 bit size key, (see Tables 4-7).…”
Section: Computational Costmentioning
confidence: 89%
See 2 more Smart Citations
“…The functions that can theoretically be activated by a remote monitoring system can be separated into three types [7].…”
Section: Medical Telemonitoringmentioning
confidence: 99%