2015
DOI: 10.1016/j.nimb.2015.04.029
|View full text |Cite
|
Sign up to set email alerts
|

He stripping for AMS of 236U and other actinides using a 3 MV tandem accelerator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0
1

Year Published

2016
2016
2021
2021

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 28 publications
(19 citation statements)
references
References 25 publications
(30 reference statements)
0
18
0
1
Order By: Relevance
“…The remaining ions are identified in the final detection system, a Bragg type ionization chamber 62 . With this setup an overall detection efficiency of 5Á10 À4 and a detection limit for 236 U/U below 10 À11 was achieved 63 . The detection efficiencies for 233 U and 236 U can be assumed to be comparable due to the similar mass of the two isotopes.…”
Section: Methodsmentioning
confidence: 96%
“…The remaining ions are identified in the final detection system, a Bragg type ionization chamber 62 . With this setup an overall detection efficiency of 5Á10 À4 and a detection limit for 236 U/U below 10 À11 was achieved 63 . The detection efficiencies for 233 U and 236 U can be assumed to be comparable due to the similar mass of the two isotopes.…”
Section: Methodsmentioning
confidence: 96%
“…The relatively high stripper gas pressure causes losses of a significant fraction of U 3+ ions to angular scattering and change exchange outside of the stripper assembly. This gives an effective stripping yield of around 21% for the charge state 3+ 50 , which is selected by the subsequent 90° analysing magnet. The combination of the analysing magnet with a Wien filter, an electrostatic analyzer, and a second 90° magnet, efficiently suppresses isotopic background on the high-energy side.…”
Section: Methodsmentioning
confidence: 99%
“…[], and Winkler et al . []. All AMS measurements of the 236 U/ 238 U isotopic ratio were performed at the Vienna Environmental Research Accelerator (VERA) facility at the University of Vienna.…”
Section: Methodsmentioning
confidence: 99%
“…The use of He and the 31 charge state provides higher detection efficiency then the previously used method employing Ar and 51 as described in Sakaguchi et al [2012]; the earlier method was, however still used for the sea water samples described in this work. Full details of AMS measurements have been described by Steier et al [2010], Sakaguchi et al [2012], and Winkler et al [2015]. All AMS measurements of the 236 U/ 238 U isotopic ratio were performed at the Vienna Environmental Research Accelerator (VERA) facility at the University of Vienna.…”
Section: Measurement Of U Isotopesmentioning
confidence: 99%