1998
DOI: 10.1021/jp9732367
|View full text |Cite
|
Sign up to set email alerts
|

He I Photoelectron Spectroscopic (PES) Study on the Electron Structure of Perchloric Acid, HOClO3, and Fluorine Perchlorate, FOClO3

Abstract: The He I photoelectron spectra (PES) of HOClO3 and FOClO3 are reported. The assignments of the PES bands are made on the basis of band shapes, relative band intensities, and the results of ab initio calculations using GAUSSIAN 94 at the 6-31G* basis set level. The two peaks (at 12.37 and 12.77 eV) in the first PES band of HOClO3 are designated as electron ionizations from HOMO 8a‘‘(25), SHOMO 7a‘‘(24), and 17a‘(23) orbitals, respectively, and they can be attributed to a Jahn−Teller effect on the largely lone-p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2007
2007
2009
2009

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 15 publications
0
2
0
Order By: Relevance
“…The experimental apparatus used in this work has been described previously. , Briefly, the photoelectron and photoionization mass spectrometer consists of two parts: one part is the double-chamber UPS-II machine; another part is a time-of-flight mass spectrometer. The photoelectron spectrum was recorded on the double-chamber UPS-II machine which was built specifically to detect transient species at a resolution of about 30 meV, as indicated by the Ar + ( 2 P 2/3 ) photoelectron band. , Experimental vertical ionization energies are calibrated by simultaneous addition of a small amount of argon and methyl iodide to the sample. Mass analysis of ions is achieved with the time-of-flight mass analyzer mounted directly to the photoionization point.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The experimental apparatus used in this work has been described previously. , Briefly, the photoelectron and photoionization mass spectrometer consists of two parts: one part is the double-chamber UPS-II machine; another part is a time-of-flight mass spectrometer. The photoelectron spectrum was recorded on the double-chamber UPS-II machine which was built specifically to detect transient species at a resolution of about 30 meV, as indicated by the Ar + ( 2 P 2/3 ) photoelectron band. , Experimental vertical ionization energies are calibrated by simultaneous addition of a small amount of argon and methyl iodide to the sample. Mass analysis of ions is achieved with the time-of-flight mass analyzer mounted directly to the photoionization point.…”
Section: Methodsmentioning
confidence: 99%
“…The photoelectron spectrum was recorded on the double-chamber UPS-II machine which was built specifically to detect transient species at a resolution of about 30 meV, as indicated by the Ar + ( 2 P 2/3 ) photoelectron band. 19,20 Experimental vertical ionization energies are calibrated by simultaneous addition of a small amount of argon and methyl iodide to the sample. Mass analysis of ions is achieved with the time-of-flight mass analyzer mounted directly to the photoionization point.…”
Section: Introductionmentioning
confidence: 99%