2015
DOI: 10.1515/cclm-2014-1005
|View full text |Cite
|
Sign up to set email alerts
|

Harmonisation of specialist training and continuing professional development in laboratory medicine: a long but necessary journey

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0
1

Year Published

2015
2015
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 14 publications
0
6
0
1
Order By: Relevance
“…One of the reasons for this discrepancy is the assay used for 25(OH)D measurements. Indeed, some assays, particularly the one used in that study (VIDAS, bioMérieux), are known to underrecover 25(OH)D in African subjects [23], whereas the Fujirebio Lumipulse assay that we used in our study is much less affected [18]. It is not entirely clear why African subjects behave differently in terms of their 25(OH)D profile, but this could be partly due to differences in the polymorphism of vitamin D–binding protein [24].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…One of the reasons for this discrepancy is the assay used for 25(OH)D measurements. Indeed, some assays, particularly the one used in that study (VIDAS, bioMérieux), are known to underrecover 25(OH)D in African subjects [23], whereas the Fujirebio Lumipulse assay that we used in our study is much less affected [18]. It is not entirely clear why African subjects behave differently in terms of their 25(OH)D profile, but this could be partly due to differences in the polymorphism of vitamin D–binding protein [24].…”
Section: Discussionmentioning
confidence: 99%
“…Third-generation assays for PTH (whole PTH) and 25(OH)D were conducted using the Fujirebio Lumipulse G 1200 analyser (Fujirebio, Tokyo, Japan). Performance of the 25(OH)D assay has been recently described [18]. The third-generation PTH assay does not cross-react with N-truncated PTH fragments that accumulate in CKD patients [19], since the antibody used only recognizes the first four amino acids of the peptide.…”
Section: Methodsmentioning
confidence: 99%
“…This experience emphasizes the importance of monitoring and controlling the many factors which are only apparently beyond the jurisdiction of the laboratory but are, on the contrary, the same problem of medical appropriateness and scientific method to the best approach to the sanitary system. [26][27][28][29][30] …”
Section: Discussionmentioning
confidence: 99%
“…Un tema ancora irrisolto è l'armonizzazione delle conoscenze e delle competenze degli specialisti in Medicina di Laboratorio, almeno all'interno dell'Unione Europea, anche alla luce delle differenze nel nome, background culturale, organizzazione delle sub-specialità, lunghezza e contenuto della formazione, responsabilità professionali, requisiti per il riconoscimento professionale e conferma dello stesso in ambito UE [17]. In un recente editoriale [44] Graham Beastall riconosce che la strada dell'armonizzazione è piuttosto lunga e che le prospettive future credibili sono relative non tanto a un'irrealistica unificazione dei contenuti e delle pratiche della specialità e delle professioni mediche e non, ma alla messa a punto di standard e formazioni che costituiscono un quadro di insieme per ridurre la variabilità degli approcci delle diverse sub-specialità e dei diversi contesti socio-professionali. Altri punti da sviluppare in un'ottica di armonizzazione sono il ruolo della leadership delle equipe di laboratorio che deve essere orientata alla clinica e le caratteristiche del continuing professional development (CPD) tale da consentire non solo l'aggiornamento delle conoscenze, ma un'armonizzazione nello sviluppo delle competenze.…”
Section: La Trasformazione Delle Professioniunclassified