2009 International Conference on Electrical Machines and Systems 2009
DOI: 10.1109/icems.2009.5382712
|View full text |Cite
|
Sign up to set email alerts
|

Harmonics and reactive power compensation method by grid-connected Photovoltaic generation system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0
2

Year Published

2012
2012
2020
2020

Publication Types

Select...
5
4
1

Relationship

0
10

Authors

Journals

citations
Cited by 20 publications
(6 citation statements)
references
References 10 publications
0
4
0
2
Order By: Relevance
“…In the other hand, at low frequencies the size and cost of the magnetic components and the link capacitor would be high to maintain the DC-link voltage ripple in acceptable operating range. Furthermore, the parasitic capacitance of the PV panels to ground could cause leakage currents due to lack of isolation [8,9]. Power electronic devices especially photovoltaic inverter, together with operation of nonlinear appliances, injects harmonics into the grid, which may potentially create voltage distortion problems.…”
Section: System Modelingmentioning
confidence: 99%
“…In the other hand, at low frequencies the size and cost of the magnetic components and the link capacitor would be high to maintain the DC-link voltage ripple in acceptable operating range. Furthermore, the parasitic capacitance of the PV panels to ground could cause leakage currents due to lack of isolation [8,9]. Power electronic devices especially photovoltaic inverter, together with operation of nonlinear appliances, injects harmonics into the grid, which may potentially create voltage distortion problems.…”
Section: System Modelingmentioning
confidence: 99%
“…Além disto, a propagação de harmônicos poder causar interferências em instrumentos mais sensíveis e eventuais ressonâncias entre equipamentos e sistemas distintos. Neste contexto, propõe-se utilizar os próprios geradores distribuídos como condicionadores de energia elétrica, tal como proposto em [15][16][17]. …”
Section: Multifuncionalidades Propostas Para O Sistema De Geraçãunclassified
“…One practical approach is that synchronous machines of old power plants are still connected to the grid and providing the reactive power and inertia [10]. It has also been a practical topic to study how the stability of the power grid can be kept in the lower rotational inertia case (because of high penetration of renewable sources) using some faster control reserves [11,12]. One possible option is to use battery storage providing primary control reserve, see e.g.…”
Section: Introductionmentioning
confidence: 99%