Harmonic Resonance Investigation of a Multi-Inverter Grid-Connected System Using Resonance Modal Analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
43
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 71 publications
(43 citation statements)
references
References 31 publications
0
43
0
Order By: Relevance
“…where V dc denotes the constant DC bus voltage, D p, ω p and D p, 2ω 0 − ω p represent the small signal responses of duty radio. The small signal models of current controller in dq domain also can be derived at frequency ω p − ω 0 and ω 0 − ω p , and are shown in (16) and (17), respectively. In (16) and (17), V cr denotes the amplitude of carrier signal which is equal to half of the DC bus voltage, G c ω p is the current controller, and G d ω p is the emulated delay effect.…”
Section: Modelling Of Single Equivalent Inverter Admittancementioning
confidence: 99%
See 2 more Smart Citations
“…where V dc denotes the constant DC bus voltage, D p, ω p and D p, 2ω 0 − ω p represent the small signal responses of duty radio. The small signal models of current controller in dq domain also can be derived at frequency ω p − ω 0 and ω 0 − ω p , and are shown in (16) and (17), respectively. In (16) and (17), V cr denotes the amplitude of carrier signal which is equal to half of the DC bus voltage, G c ω p is the current controller, and G d ω p is the emulated delay effect.…”
Section: Modelling Of Single Equivalent Inverter Admittancementioning
confidence: 99%
“…Combining the models of power stage circuit (14), (15) and current controller (16), (17) through Park transformation model (10), (11), self-admittance Y SA and accompanying-admittance Y AA for the inverter itself can be derived as shown in (18) and (19).…”
Section: Modelling Of Single Equivalent Inverter Admittancementioning
confidence: 99%
See 1 more Smart Citation
“…Several studies have been conducted to mitigate the interactive resonance by introducing a virtual harmonic resistance [5], an active damper based on a high-bandwidth power converter [8], or capacitor current-based active damping [9][10][11]. The interactive resonance causes a mutual current-also known as an interactive current-which circulates among inverters instead of flowing into the grid.…”
Section: Literature Reviewmentioning
confidence: 99%
“…current regulation of any other j inverters. The control plant, which comprises multi-parallel GCIs in the discrete time domain is represented as a block-diagram according to Equation Energies 2019, 12, 4363 7 of 21(9). With the consideration of the zero-order-hold (ZOH) effect inFigure 3, the discrete representations of G d plant (s) and G d coupling (s) are given as[24] …”