2003 IEEE Bologna Power Tech Conference Proceedings,
DOI: 10.1109/ptc.2003.1304365
|View full text |Cite
|
Sign up to set email alerts
|

Harmonic interaction between large numbers of photovoltaic inverters and the distribution network

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
17
0
1

Publication Types

Select...
4
4
2

Relationship

2
8

Authors

Journals

citations
Cited by 52 publications
(18 citation statements)
references
References 5 publications
0
17
0
1
Order By: Relevance
“…In this study, only the series resonance is evaluated, since it is caused mainly by the considerable presence of electronic loads in the households, which contains capacitors connected between the terminals. An equivalent capacitance of 3 µF was considered, following the reference values given by the authors in [18] for resonance studies. The main characteristics of the network impedance were adjusted in accordance with [19], which gives guidance for determining the reference impedances for use in determining disturbance characteristics of electrical equipment.…”
Section: E Network Impedancementioning
confidence: 99%
“…In this study, only the series resonance is evaluated, since it is caused mainly by the considerable presence of electronic loads in the households, which contains capacitors connected between the terminals. An equivalent capacitance of 3 µF was considered, following the reference values given by the authors in [18] for resonance studies. The main characteristics of the network impedance were adjusted in accordance with [19], which gives guidance for determining the reference impedances for use in determining disturbance characteristics of electrical equipment.…”
Section: E Network Impedancementioning
confidence: 99%
“…Even and odd harmonics In [1] it was assumed that the inverters behave similarly for even and odd harmonics. The measurements performed within this research however show that this is not the case.…”
Section: Model Parametersmentioning
confidence: 99%
“…However, similar studies applied to 3-phase transformer-less PV inverters still require further investigation, which can be applicable from small domestic installations to large-scale PV stations. In 2003 Enslin [14] investigated the dominating mechanisms of interaction between large populations of PV inverters and the electrical distribution system. More specifically, this study analyses the observed phenomena of harmonic interference and provides some explanation of the resonance between existing network components and the PV inverters.…”
Section: Introductionmentioning
confidence: 99%