2008
DOI: 10.1016/j.jneumeth.2007.12.015
|View full text |Cite
|
Sign up to set email alerts
|

Hardware and methodology for targeting single brain arterioles for photothrombotic stroke on an upright microscope

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
58
0

Year Published

2008
2008
2016
2016

Publication Types

Select...
4
4

Relationship

1
7

Authors

Journals

citations
Cited by 52 publications
(58 citation statements)
references
References 16 publications
0
58
0
Order By: Relevance
“…The procedures for laser speckle imaging have been described previously (Dunn et al, 2001;Sigler et al, 2008). Briefly, the cortical surface was illuminated by a 784 nm, 32 mW StockerYale SNF-XXX-785S-35 laser (StockerYale) with an Edmund Optics anamorphic beam expander T47274 (Edmund Optics), and 50 -150 images at 30 Hz using 10 -15 ms exposure were collected with a Dalsa M60 Pantera camera (Dalsa).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The procedures for laser speckle imaging have been described previously (Dunn et al, 2001;Sigler et al, 2008). Briefly, the cortical surface was illuminated by a 784 nm, 32 mW StockerYale SNF-XXX-785S-35 laser (StockerYale) with an Edmund Optics anamorphic beam expander T47274 (Edmund Optics), and 50 -150 images at 30 Hz using 10 -15 ms exposure were collected with a Dalsa M60 Pantera camera (Dalsa).…”
Section: Methodsmentioning
confidence: 99%
“…5C) and could account for some of the spared dendrites. Across the laser speckle image, a gradual darkening is apparent toward the medial portion of the image and is attributed to diffusion in microvessels (Dunn et al, 2001;Yuan et al, 2005;Sigler et al, 2008), indicating higher levels of local blood flow.…”
Section: Blood Flow and Structural Change During Mcaomentioning
confidence: 99%
“…Although laser-mediated excitation was still used recently5, it can be replaced by cold light lamp that also ensure dye excitation 10,15 . Cold light optic fibers are easier to manipulate and less expensive than laser sources.…”
Section: Modifications and Substitutionsmentioning
confidence: 99%
“…Cold light optic fibers are easier to manipulate and less expensive than laser sources. However, it should be noticed that lasers are commonly used to target individual surface arterioles after craniotomy for an in vivo vessel-specific clotting 10 .…”
Section: Modifications and Substitutionsmentioning
confidence: 99%
“…We have recently used it to examine the relationship between changes in blood flow and changes in neuronal structure and function with a modified setup. 30 The work by Zhang and Murphy 26 combined structural assessment of neurons using yellow fluorescent protein fluorescence with 2-photon analysis of blood flow as well as functional measures, including intrinsic optical signals, that defined the range with which individual blood vessels maintain synaptic structure and function, discussed in more detail subsequently.…”
Section: Fluorescent Dextran Imaging Of Vascular Structure and Functimentioning
confidence: 99%