“…Scoping tests were conducted to assess the effects of adding up to 5 wt% fluoride, 5 wt% BaO, 5 wt% MnO,, 2 wt% MOO,, and 2 wt% NiO to HW39 borosilicate glass (Larson 1989). During the performance of these tests, only 60 to 80 percent of the fluoride was retained in the sample glass.…”
Section: Chloride and Fluoride Solubilitymentioning
confidence: 99%
See 1 more Smart Citation
“…Scoping tests were conducted to assess the effects of adding up to 5 wt% fluoride, 5 wt% BaO, 5 wt% MnO,, 2 wt% MOO,, and 2 wt% NiO to HW39 borosilicate glass (Larson 1989). During the performance of these tests, only 60 to 80 percent of the fluoride was retained in the sample glass.…”
Section: Chloride and Fluoride Solubilitymentioning
confidence: 99%
“…In a study of sulfate in borosilicate glass, the Fe+'/Fe+, ratio was systematically varied from 0 to 2.5 for glasses in which 0.5 and 1.0 wt%sulfate wereadded WNCAW at 25 percent WOL (Larson 1989, Bates et al 1985. The sulfate solubility did not change for the sample with 0.5 wt% sulfate over the REDOX range of interest (0.0 to 0.3).…”
Section: Sulfate Solubilitymentioning
confidence: 99%
“…The HLW melters can have chrome refractories throughout the melter because the color of the product glass is not important At 1OS0°C to llS0°C, reported colTOsion rates for carborundum K-3 in contact with borosilicate glass were 10 to 20 J.IIIlI'day at the melt line, and less than 10 J.IIIlI'day below the glass surface. The K-3 corrosion rate measured during a rebuild of the PSCM at PNL was 4 to 8 J.IIIlI'day (Larson 1989a). The fused cast refractory in the previous HWVPIDWPF design was 12 in.…”
Section: Modular Design Concepts That Simplify Replacement or Repairmentioning
confidence: 95%
“…Failure of the plenum refractory has mainly been associated with improper hangers or inadequate allocation for thermal expansion (Larson 1989b). …”
Section: Modular Design Concepts That Simplify Replacement or Repairmentioning
confidence: 99%