1983
DOI: 10.1109/tim.1983.4315097
|View full text |Cite
|
Sign up to set email alerts
|

Hall-Plate Measurements of Magnetite Buildup in Pressurized-Water Reactor Steam Generators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
5
0

Year Published

1986
1986
1995
1995

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 3 publications
0
5
0
Order By: Relevance
“…This model has been accepted as a. standard in fracture mechanics. Lecvkage field profile.^ liave been predicted by Lord and Hwang [43,44] and Satisli [4][5]46] by modeling Poisson"s equation in 2D. Lord, et al [47] took the process one step further and studied leakage field profiles for 3D pipeline structures.…”
Section: Finite Elementsmentioning
confidence: 99%
“…This model has been accepted as a. standard in fracture mechanics. Lecvkage field profile.^ liave been predicted by Lord and Hwang [43,44] and Satisli [4][5]46] by modeling Poisson"s equation in 2D. Lord, et al [47] took the process one step further and studied leakage field profiles for 3D pipeline structures.…”
Section: Finite Elementsmentioning
confidence: 99%
“…Figure 1. a) shows a variable reluetanee (VR) probe whieh has been used to deteet magnetite buildup in the ereviee gap region between the ineoncl steam generator tubes and earbon steel support plates of a nuclear power plant steam generator unit [3). The bobbin-shaped probe earries ade excitation winding and the Hall plate measures the radial eomponent ofmagnetie flux density at one end of the soft iron bobbin.…”
Section: Upwinding Finite Element Formulationmentioning
confidence: 99%
“…As a specific example ofthe probe velocity effccts on the MFL output signal, a 'support plate signal' of a simple dc variable reluctance probe (Fig. 1), which has been used for steam generator tubing inspection [1,2,3], is studied. To suppress spurious oscillations, an upwinding technique is applied in the numerical analysis.…”
mentioning
confidence: 99%
“…RESULTS Figure 1. a) shows a variable reluetanee (VR) probe whieh has been used to deteet magnetite buildup in the ereviee gap region between the ineoncl steam generator tubes and earbon steel support plates of a nuclear power plant steam generator unit [3). The bobbin-shaped probe earries ade excitation winding and the Hall plate measures the radial eomponent ofmagnetie flux density at one end of the soft iron bobbin.…”
Section: Upwinding Finite Element Formulationmentioning
confidence: 99%