2009 IEEE International Conference on Control and Automation 2009
DOI: 10.1109/icca.2009.5410175
|View full text |Cite
|
Sign up to set email alerts
|

H<inf>&#x221E;</inf> fuzzy tracking control for boiler-turbine systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
4
2

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(12 citation statements)
references
References 18 publications
0
12
0
Order By: Relevance
“…The TS fuzzy models of the boilerturbine unit used in this work are derived from [49,52,53]. A guaranteed cost controller was developed in [49], and H∞ robust controllers were developed in [52,53]. The control laws were developed based on state feedback in [49,52,53].…”
Section: Lemma 1 ([45]mentioning
confidence: 99%
“…The TS fuzzy models of the boilerturbine unit used in this work are derived from [49,52,53]. A guaranteed cost controller was developed in [49], and H∞ robust controllers were developed in [52,53]. The control laws were developed based on state feedback in [49,52,53].…”
Section: Lemma 1 ([45]mentioning
confidence: 99%
“…Furthermore, an H ∞ fuzzy state-feedback controller is implemented once the control system meets a certain switching principle. This controller has shown good results in the application to the boiler-turbine unit [8]. The control setup is depicted in Fig.…”
Section: Constrained Boiler-turbine Modelmentioning
confidence: 99%
“…One of the drawbacks is the complicated adaptive scheme. In [8], an H ∞ fuzzy control is presented which exploits the form of the system nonlinearities. It shows good tracking behavior for large changes in the reference signal as is used here to stabilize the plant once the tracking error is sufficiently small.…”
Section: Introductionmentioning
confidence: 99%
“…After that the boiler-turbine's nonlinear model was studied widely in many art icles and was undergone a number of amends to provide a better description of system [2,3]. In o rder to design a controller some researchers used nonlinear form of system's equations [5,6,10 ] and in other works the linear fo rm o f the system was used [4,[7][8][9].…”
Section: Introductionmentioning
confidence: 99%
“…Th is system is strongly coupled and is subject to various constraints on both inputs and outputs. In literatures that used the linearized form of boiler-turbine system, they obtained a linearized model using a truncated Ty lo r series expans io n of n on lin ear equations around operating points [4,[7][8][9]. Linearization around operating points provides a relatively accurate description about system behaviour around these points, however for using of this method we should have nominal states' and inputs' values at operating points which are not readily availab le.…”
Section: Introductionmentioning
confidence: 99%