2020
DOI: 10.4103/2543-1463.282192
|View full text |Cite
|
Sign up to set email alerts
|

Guidelines for the Use of Echocardiography as a Monitor for Therapeutic Intervention in Adults

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
98
1
7

Year Published

2020
2020
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 67 publications
(106 citation statements)
references
References 93 publications
0
98
1
7
Order By: Relevance
“…It is also recommended that TEE operators, commonly anesthesiologists with expertise in cardiothoracic cases and/or management of complex vascular surgical cases, have specific TEE training in order to appropriately guide clinical decision-making. 38 To further enhance the use of TEE, having the same operator throughout case is valuable in detecting dynamic changes, as even quantitative measures demonstrate intra-operator variability, and can require subjective judgment and case familiarity. 38 While there is extensive literature published on the role of TEE in treating RCC with IVC thrombus, no study has demonstrated definitively superior outcomes with its use.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…It is also recommended that TEE operators, commonly anesthesiologists with expertise in cardiothoracic cases and/or management of complex vascular surgical cases, have specific TEE training in order to appropriately guide clinical decision-making. 38 To further enhance the use of TEE, having the same operator throughout case is valuable in detecting dynamic changes, as even quantitative measures demonstrate intra-operator variability, and can require subjective judgment and case familiarity. 38 While there is extensive literature published on the role of TEE in treating RCC with IVC thrombus, no study has demonstrated definitively superior outcomes with its use.…”
Section: Discussionmentioning
confidence: 99%
“…38 To further enhance the use of TEE, having the same operator throughout case is valuable in detecting dynamic changes, as even quantitative measures demonstrate intra-operator variability, and can require subjective judgment and case familiarity. 38 While there is extensive literature published on the role of TEE in treating RCC with IVC thrombus, no study has demonstrated definitively superior outcomes with its use. This is a potential area of further investigation, which would help to validate future guidelines that may advocate for its use.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…well as TDI)34 were strongly dependent on the insonation angle and the specific location of the sample. Both the STE49,50 and the 3D 28,47 overcome this weakness of the Doppler-based techniques;(b) the LVOT-VTI values reflect a surrogate of the SV without providing additional information on regional or global motility, while the TDI,34,48 STE,49,50 and the 3DE 28,47 provide specific and sensitive information for quantification of global and regional LV contractile function; (c) the dependency from geometric assumptions about LV and LVOT shape33 (in contrast with STE 49,50 and 3DE techniques) 28,47.…”
mentioning
confidence: 99%
“…Both the STE49,50 and the 3D 28,47 overcome this weakness of the Doppler-based techniques;(b) the LVOT-VTI values reflect a surrogate of the SV without providing additional information on regional or global motility, while the TDI,34,48 STE,49,50 and the 3DE 28,47 provide specific and sensitive information for quantification of global and regional LV contractile function; (c) the dependency from geometric assumptions about LV and LVOT shape33 (in contrast with STE 49,50 and 3DE techniques) 28,47. The Guidelines for the Use of Echocardiography as a Monitor for Therapeutic Intervention in Adults considered a single cutoff value (18 cm) for LVOT-VTI 34. That single cutoff value was established considering data from adults 42,51.…”
mentioning
confidence: 99%