2018
DOI: 10.14316/pmp.2018.29.4.123
|View full text |Cite
|
Sign up to set email alerts
|

Guideline on Acceptance Test and Commissioning of High-Precision External Radiation Therapy Equipment

Abstract: The complex dose distribution and dose transfer characteristics of intensity-modulated radiotherapy increase the importance of precise beam data measurement and review in the acceptance inspection and preparation stages. In this study, we propose a process map for the introduction and installation of high-precision radiotherapy devices and present items and guidelines for risk management at the acceptance test procedure (ATP) and commissioning stages. Based on the ATP of the Varian and Elekta linear accelerato… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0
1

Year Published

2023
2023
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 9 publications
0
2
0
1
Order By: Relevance
“…Immediately after the FLEX conversion of the linac to operate with 16 MeV eFLASH, a radiation survey was conducted to ensure safety. Next, acceptance tests and additional dosimetric characterization of the 16 MeV eFLASH beam were conducted based on the guiding principles for conventional radiotherapy 18–20 …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Immediately after the FLEX conversion of the linac to operate with 16 MeV eFLASH, a radiation survey was conducted to ensure safety. Next, acceptance tests and additional dosimetric characterization of the 16 MeV eFLASH beam were conducted based on the guiding principles for conventional radiotherapy 18–20 …”
Section: Methodsmentioning
confidence: 99%
“…Next, acceptance tests and additional dosimetric characterization of the 16 MeV eFLASH beam were conducted based on the guiding principles for conventional radiotherapy. 18 , 19 , 20 …”
Section: Methodsmentioning
confidence: 99%
“…De acordo com o ICRU (1), para radioterapia com uso de alta tecnologia, como a de intensidade modulada (IMRT -Intensity-modulated Radiation Therapy), a utilização de dosimetria computacional e imagens 3D é essencial. A distribuição de dose complexa e as características da liberação de dose na IMRT aumentaram a importância de medições precisas dos feixes de aceleradores lineares (2). O processo de aquisição desses dados e inserção deles no Sistema de Planejamento de Tratamento (TPS -Treatment Planning System) chama-se comissionamento, e o mais conveniente equipamento para obtenção de tais dados é um sistema automatizado de varredura de campo de radiação 3 .…”