Ground-Fault Characteristic Analysis of Grid-Connected Photovoltaic Stations with Neutral Grounding Resistance

Abstract: Abstract:A centralized grid-connected photovoltaic (PV) station is a widely adopted method of neutral grounding using resistance, which can potentially make pre-existing protection systems invalid and threaten the safety of power grids. Therefore, studying the fault characteristics of grid-connected PV systems and their impact on power-grid protection is of great importance. Based on an analysis of the grid structure of a grid-connected PV system and of the low-voltage ride-through control characteristics of a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 26 publications
(22 reference statements)
0
6
0
Order By: Relevance
“…According to the simultaneous equation of Equations (4) and (6), the DC bus fault component voltage equation is…”
Section: Symmetrical Fault Conditionmentioning
confidence: 99%
See 1 more Smart Citation
“…According to the simultaneous equation of Equations (4) and (6), the DC bus fault component voltage equation is…”
Section: Symmetrical Fault Conditionmentioning
confidence: 99%
“…In [3][4][5][6][7], the characteristics and calculation methods of the steady-state fault current of PV power have been studied without considering its transient fault characteristics, therefore the conclusions 2 of 21 are only applicable to the steady-state short-circuit analysis. In [8], the mathematical model for the fault analysis of inverter interfaced distributed generator (IIDG) has been first established by using single outer voltage loop control strategy, and then the fault analysis method of distribution network including IIDG has been proposed.…”
Section: Introductionmentioning
confidence: 99%
“…Existing research on system grounding types is mainly focused on the grounding fault analysis based on different grounding types [19][20][21][22]. In [19], the fault models of a low voltage power system are developed for the system grounding fault analysis, and the variation of fault current with grounding resistance has been acquired based on the system fault analysis.…”
Section: Introductionmentioning
confidence: 99%
“…In [19], the fault models of a low voltage power system are developed for the system grounding fault analysis, and the variation of fault current with grounding resistance has been acquired based on the system fault analysis. A fault-calculation method for a grid-connected PV station is proposed in [20] based on the fault characteristics analysis of the system. In [21], a DC link adjustable resistive type fault current limiter based on fault analysis of converter is proposed to improve fault ride-through capability.…”
Section: Introductionmentioning
confidence: 99%
“…A novel relay protection scheme using directional distance components was proposed in [25], [26], but this scheme is only for the phase-to-phase faults. A fault calculation model of the large-scale PVPS is established in [27], which analyzes the ground fault characteristic of the convergence bus and collector lines and their impacts on protection. Given that, a neutral grounding resistance selection scheme is proposed in [28], but no consideration is given to the coordination of protection and LVRT requirements.…”
Section: Introductionmentioning