2020
DOI: 10.1002/2050-7038.12189
|View full text |Cite
|
Sign up to set email alerts
|

Grid frequency enhancement using coordinated action of wind unit with redox flow battery in a deregulated electricity market

Abstract: Summary Growing electricity demand, environmental issues, and challenge to decrease dependence on fossil fuel resources have increased the inception of wind generation into the power system. However, higher penetration of wind‐based generating units into the existing grid can affect the working of the power system. Traditionally, a wind unit does not provide inertia, but collectively, wind units can have a notable impact on the dynamic performance of the power system. However, the battery energy storage system… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
36
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
1
1

Relationship

3
3

Authors

Journals

citations
Cited by 27 publications
(36 citation statements)
references
References 57 publications
0
36
0
Order By: Relevance
“…The timedomain simulations have been carried out to investigate the system performances under most likely operating conditions/scenarios of the MG system. The relevant data used in the studied power system have been given in the Appendix [8,10,30,36,41,48]. The four scenarios considered to evaluate the role of energy storage systems (battery and MPHES) in order to enhance the dynamic performance of the MG system are as follows.…”
Section: Simulation Results and Analysismentioning
confidence: 99%
See 2 more Smart Citations
“…The timedomain simulations have been carried out to investigate the system performances under most likely operating conditions/scenarios of the MG system. The relevant data used in the studied power system have been given in the Appendix [8,10,30,36,41,48]. The four scenarios considered to evaluate the role of energy storage systems (battery and MPHES) in order to enhance the dynamic performance of the MG system are as follows.…”
Section: Simulation Results and Analysismentioning
confidence: 99%
“…After optimal tuning, the controller supplies the coveted and suitable signal to the generating units in reference to the load change to enhance the dynamic performance of the proposed control framework. In this study, the integral of time multiplied absolute error (ITAE) criterion is regarded as the objective function that can be expressed by the following equations [48]:…”
Section: Objective Function Formulation To Design An Optimal Controllermentioning
confidence: 99%
See 1 more Smart Citation
“…Although, the sturdiness of the offered control methodology is also already established for all possible transactions in the deregulated market for the same optimal parameters in all cases. Further, the performance of the proposed controller is also tested for different DPM as given in (32), 43…”
Section: Sensitivity Analysismentioning
confidence: 99%
“…Although, the sturdiness of the offered control methodology is also already established for all possible transactions in the deregulated market for the same optimal parameters in all cases. Further, the performance of the proposed controller is also tested for different DPM as given in (32), 43 obtained responses as in Figures 16E,F shows that proposed controller work incomparably over other methods with new DPM and power flows are according to the set contract. Hence, the robustness of the offered control methodology is verified for deviation in parameters, a different type of nonlinearities, different DPMs, and possible transactions in a deregulated market. DPM=[]0.100.30.40.30.40.1000.100.20.20.20.40.20.20.300.10.200.20.1 …”
Section: Sensitivity Analysismentioning
confidence: 99%