2008
DOI: 10.1016/j.solener.2007.10.006
|View full text |Cite
|
Sign up to set email alerts
|

Grid-connected photovoltaic system using current-source inverter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2008
2008
2018
2018

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(10 citation statements)
references
References 2 publications
0
10
0
Order By: Relevance
“…Some research [7,8] show that three-phase CSI direct voltage will produce 6,12,18 characteristic harmonic and 2,4,8,10 Non-characteristic Harmonic when three-phase unbalance. Direct voltage harmonic lead rectifier to produce DC current harmonic, in reverse, the DC current harmonic influence the waveform of alternating current current.…”
Section: Discussion: Analyze Of Errormentioning
confidence: 99%
See 1 more Smart Citation
“…Some research [7,8] show that three-phase CSI direct voltage will produce 6,12,18 characteristic harmonic and 2,4,8,10 Non-characteristic Harmonic when three-phase unbalance. Direct voltage harmonic lead rectifier to produce DC current harmonic, in reverse, the DC current harmonic influence the waveform of alternating current current.…”
Section: Discussion: Analyze Of Errormentioning
confidence: 99%
“…At this time, power grid side of rectifier show a negative resistance, power grid absorb positive power, realize the high power factor of battery power to feedback to network [7], (see Figure 1.) The CSI can change the output voltage polarity, but can't change the flow direction of output current.…”
Section: Converter Structure and Work Theorymentioning
confidence: 99%
“…Three-phase Current Source Inverters (CSI) operate similarly to three-phase VSI but injecting an average sinusoidal current in each phase [11], [25]. The topology of a Two-Level Current-Source inverter is shown in Fig.…”
Section: Current Source Invertermentioning
confidence: 99%
“…There are other topologies like the multilevel and interleaved [4] that have recently aroused the interest of researchers in microgrids. Other power converters recently proposed for MG applications are the current source inverters [10], [11], matrix inverters [12], [13] and solid state transformers [14].…”
mentioning
confidence: 99%
“…Each one includes two switches which are complementary and controlled by the Pulse Width Modulation PWM, as in (Lee et al, 2008;Weslati et al, 2008;Yu et al, 2006). The inverter's voltages (V a , V b , V c ) are expressed in terms of the upper switches as follows:…”
Section: Modeling Of the Pvgmentioning
confidence: 99%