2020
DOI: 10.1016/j.solener.2020.02.045
|View full text |Cite
|
Sign up to set email alerts
|

Grid-connected photovoltaic system employing a single-phase T-type cascaded H-bridge inverter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 30 publications
(5 citation statements)
references
References 31 publications
0
3
0
Order By: Relevance
“…The logic behind this is to simulate the consumption of various types of energy within the building and calculate carbon emissions based on the carbon emission coefficients of these energy sources. Internationally recognized energy simulation software includes EnergyPlus, OpenStudio, DesignBuilder, DesT, IES-VE, and TRNSYS, among others [4]. EnergyPlus is a widely used international energy simulation engine, and it includes a program for whole-life cycle calculations.…”
Section: Carbon Emission Calculation Methods During Operational Phasementioning
confidence: 99%
“…The logic behind this is to simulate the consumption of various types of energy within the building and calculate carbon emissions based on the carbon emission coefficients of these energy sources. Internationally recognized energy simulation software includes EnergyPlus, OpenStudio, DesignBuilder, DesT, IES-VE, and TRNSYS, among others [4]. EnergyPlus is a widely used international energy simulation engine, and it includes a program for whole-life cycle calculations.…”
Section: Carbon Emission Calculation Methods During Operational Phasementioning
confidence: 99%
“…A power switch and series diode are present in the interleaved cell. The reference current is considered as the direction of current into phase-leg [34][35][36]. The switch 1 s is "ON" means the reference current is positive and if it "OFF" means than the reference current is negative.…”
Section: Operating Principle Of Interleaved Invertermentioning
confidence: 99%
“…Compared with other traditional topologies, T-type topology delivers an extraordinary improvement regarding the lower count of switches used and lower layout complexity. Further, almost 40-50% reduction in power switch count is achieved without diodes or capacitors [173]. This configuration has an H-bridge and an auxiliary bidirectional switch for controlling the connection of the supply from the DC sources to generate the staircase output voltage.…”
Section: A T-type Multilevel Invertermentioning
confidence: 99%