Greenhouse heating using heat pumps with a high coefficient of performance (COP)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

4
17
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 79 publications
(29 citation statements)
references
References 22 publications
4
17
0
Order By: Relevance
“…Figure 3 shows the relationship between the daily number of reverse cycle defrostings and COP air . The daily number of reverse cycle defrostings ranged from 0 to 44, and COP air decreased as the daily number of reverse cycle defrostings increased, which is consistent with previous reports (Tong et al, 2010;Sasaki, 1989). Tong et al (2010) indicated that COP values were affected by T out and relative humidity, as well as the frequency and duration of reverse cycle defrosting.…”
Section: Operating Characteristics Of the Ashpsupporting
confidence: 80%
See 2 more Smart Citations
“…Figure 3 shows the relationship between the daily number of reverse cycle defrostings and COP air . The daily number of reverse cycle defrostings ranged from 0 to 44, and COP air decreased as the daily number of reverse cycle defrostings increased, which is consistent with previous reports (Tong et al, 2010;Sasaki, 1989). Tong et al (2010) indicated that COP values were affected by T out and relative humidity, as well as the frequency and duration of reverse cycle defrosting.…”
Section: Operating Characteristics Of the Ashpsupporting
confidence: 80%
“…The daily number of reverse cycle defrostings ranged from 0 to 44, and COP air decreased as the daily number of reverse cycle defrostings increased, which is consistent with previous reports (Tong et al, 2010;Sasaki, 1989). Tong et al (2010) indicated that COP values were affected by T out and relative humidity, as well as the frequency and duration of reverse cycle defrosting. Although the frequency and duration of reverse cycle defrosting are not described in this paper, values were reported by Furuno et al (2012) for the same ASHP as that used here.…”
Section: Operating Characteristics Of the Ashpsupporting
confidence: 80%
See 1 more Smart Citation
“…The demand for district heating is more or less constant whilst that for cooling has increased significantly in recent years: it has doubled in Sweden in the past 10 years [1]. Today's electrically powered heat pumps for producing cooling are highly efficient, with a coefficient of performance (COP) > 4 [2]. However, they are driven by a high-quality form of energy, i.e.…”
Section: Introductionmentioning
confidence: 99%
“…The study of this paper is based on solar heat collection heating system, which turn the clean energy solar energy into the energy of the water of the pipes underground through the heat exchanger in daytime, and when the hot water reaches the set heating temperature, it will be carried to the pipeline of the greenhouse, which will heat the greenhouse [4] [5].…”
Section: Introductionmentioning
confidence: 99%