Green approaches to comprehensive two-dimensional liquid chromatography (LC × LC)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 29 publications
0
3
0
Order By: Relevance
“…The authors revealed that the effective peak distribution and peak capacity obtained with PC as an organic modifier were comparable to those obtained using ACN and MeOH. Despite the significantly reduced runtime (32 min for methods with PC vs 52 min for methods with ACN and MeOH), an improvement in separation selectivity was achieved [48]. Тhis research confirmed the role of propylene carbonate as an effective substitute for acetonitrile, providing greater separation power even in 2D LC.…”
Section: Propylene Carbonatementioning
confidence: 69%
See 1 more Smart Citation
“…The authors revealed that the effective peak distribution and peak capacity obtained with PC as an organic modifier were comparable to those obtained using ACN and MeOH. Despite the significantly reduced runtime (32 min for methods with PC vs 52 min for methods with ACN and MeOH), an improvement in separation selectivity was achieved [48]. Тhis research confirmed the role of propylene carbonate as an effective substitute for acetonitrile, providing greater separation power even in 2D LC.…”
Section: Propylene Carbonatementioning
confidence: 69%
“…The most recent research that demonstrates the applicability of PC as a replacement for ACN has focused on the separation of a mixture of 39 pharmaceutical compounds in two-dimensional liquid chromatography (2D LC) [48]. The authors revealed that the effective peak distribution and peak capacity obtained with PC as an organic modifier were comparable to those obtained using ACN and MeOH.…”
Section: Propylene Carbonatementioning
confidence: 99%
“…PC can be used to separate 39 medicinal substances mixture using two-dimensional liquid chromatography (2D LC). Despite having a substantially shorter duration, the study indicated that PC's effective peak distribution and peak capacity as an organic modifier were equivalent to those of ACN and MeOH (52 minutes for ACN and MeOH against 32 minutes for PC) [24]. PC Propylene carbonate is an effective substitute for acetonitrile, providing greater separation power in 2D LC, opening the possibility for wider applications.…”
Section: Green Solvents As a Mobile Phasementioning