2016
DOI: 10.1021/acs.analchem.6b02678
|View full text |Cite
|
Sign up to set email alerts
|

Greatly Increasing Trapped Ion Populations for Mobility Separations Using Traveling Waves in Structures for Lossless Ion Manipulations

Abstract: The initial use of traveling waves (TW) for ion mobility (IM) separations using structures for lossless ion manipulations (SLIM) employed an ion funnel trap (IFT) to accumulate ions from a continuous electrospray ionization source and was limited to injected ion populations of ~106 charges due to the onset of space charge effects in the trapping region. Additional limitations arise due to the loss of resolution for the injection of ions over longer periods, such as in extended pulses. In this work a new SLIM “… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
40
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7
2

Relationship

4
5

Authors

Journals

citations
Cited by 29 publications
(41 citation statements)
references
References 38 publications
0
40
0
Order By: Relevance
“…20 The SLIM designs used a pair of evenly spaced surfaces (~3 mm gap) having mirror-image arrays of six rf strip electrodes and lateral ion-confining dc “guard” electrodes, as described previously. 13,16 Five strips of segmented TW electrodes of 1.03 mm length and 0.43 mm width were interspersed between adjacent oppositely phased rf electrodes (a small portion of one surface is shown in the inset of Figure 1a).…”
Section: Methodsmentioning
confidence: 99%
“…20 The SLIM designs used a pair of evenly spaced surfaces (~3 mm gap) having mirror-image arrays of six rf strip electrodes and lateral ion-confining dc “guard” electrodes, as described previously. 13,16 Five strips of segmented TW electrodes of 1.03 mm length and 0.43 mm width were interspersed between adjacent oppositely phased rf electrodes (a small portion of one surface is shown in the inset of Figure 1a).…”
Section: Methodsmentioning
confidence: 99%
“…54 Three independently-controlled traveling waveforms provided ion transmission from the source to the trap section (i.e., ion filling), the release of ions from the trapping section (i.e., ion ejection) and transferring ions through a funnel-shaped section to a time-of-flight MS (Figure 14). The flat funnel was operated at ~3 Torr and used two TWs that were applied to two sets of interleaving TW electrodes in the trap section.…”
Section: Ion Trappingmentioning
confidence: 99%
“…The IFT was used in continuous mode. 54 Adapted with permission from ref. 54 , Copyright (2016) American Chemical Society.…”
Section: Figurementioning
confidence: 99%
“…1012 The rung electrodes in the TW-SLIM used long rf electrodes separated by segmented dc electrodes. TW-SLIM IM modules were found to have similar capabilities to the uniform-field SLIM modules 1014 and allowed for extended path lengths, thus achieving higher IM resolutions in relatively compact devices. 1014 TW-SLIM modules were also demonstrated to enable the trapping of much larger ion populations and the ability to perform IM peak “compression”, of great utility for reversing peak diffusional growth and loss of peak intensities in extended ultrahigh resolution IM separations.…”
mentioning
confidence: 96%