2015
DOI: 10.1007/s00604-015-1508-6
|View full text |Cite
|
Sign up to set email alerts
|

Graphene quantum dots as on-off-on fluorescent probes for chromium(VI) and ascorbic acid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
66
1

Year Published

2017
2017
2022
2022

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 129 publications
(72 citation statements)
references
References 32 publications
5
66
1
Order By: Relevance
“…In fact, the present detection limit is quite lower than the acceptance limit specified by WHO. Moreover, the comparison of LOD for Cr 6+ reported in the literature, as shown in Table , highlights the superior detection efficiency of the present detection system, besides the work done by Zhang et al and Huang et al Most importantly, the CDs have been used without further purification and stabilization in the proposed technique of the present study.…”
Section: Resultsmentioning
confidence: 58%
“…In fact, the present detection limit is quite lower than the acceptance limit specified by WHO. Moreover, the comparison of LOD for Cr 6+ reported in the literature, as shown in Table , highlights the superior detection efficiency of the present detection system, besides the work done by Zhang et al and Huang et al Most importantly, the CDs have been used without further purification and stabilization in the proposed technique of the present study.…”
Section: Resultsmentioning
confidence: 58%
“…[38] and, along with the absorption curve and the dependence of the emission peak on the excitation wavelength (Fig. 1b,c), showed the characteristic spectral features found in regular GOQDs synthesized from graphite or citric acid [28][29][30][31][32][33][34] [35]. In particular, the absorption spectrum (Fig.…”
Section: Optical Characterization Of Ufqdsmentioning
confidence: 93%
“…Electron transfer to partly filled d orbitals or complexation with layer aggregation were taken into account to explain the two cases, respectively. Finally, a selective response to Cr 6+ was found at pH 4.5 in commercially available GQDs [34]. It should be pointed out that such a surprising and somehow puzzling variety of response, in some cases with contradictory results, was obtained in carbon quantum dots which should basically share a similar structure modelled on graphene, i.e.…”
Section: +mentioning
confidence: 96%
See 1 more Smart Citation
“…Most importantly, some recent studies [4][5][6][7] have demonstrated that the PL intensity is significantly quenched in the presence of certain heavy-metal ions (Hg 2+ , Fe 2+ , Cu 2+ , Pb 2+ ), thus triggering the interest of researchers in view of fast and cheap sensors for these elements.…”
Section: Introductionmentioning
confidence: 99%