2016
DOI: 10.1016/j.talanta.2016.07.039
|View full text |Cite
|
Sign up to set email alerts
|

Graphene oxide based electrochemical label free immunosensor for rapid and highly sensitive determination of tumor marker HSP70

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 32 publications
(11 citation statements)
references
References 36 publications
0
11
0
Order By: Relevance
“…The increase in the real and the imaginary parts of the impedance and thus the impedance modulus (|Z|) confirms the BSA’s immobilization on all electrodes, which causes an increase in the charge transfer resistance. , The lowest value of the impedance module registered for the lowest frequency (0.1 Hz) was noted for the TNT sample and, what is essential, the |Z| value was precisely the same for both immobilization times, which proves the complete saturation of the TNT layer only after 0.5 h of the protein deposition. Similar to TNTs, comparable changes in impedance parameters for both immobilization times are recorded for the 10sd_AgNPs/TNT electrode, which is why it was considered that half an hour is sufficient to saturate this platform.…”
Section: Resultsmentioning
confidence: 99%
“…The increase in the real and the imaginary parts of the impedance and thus the impedance modulus (|Z|) confirms the BSA’s immobilization on all electrodes, which causes an increase in the charge transfer resistance. , The lowest value of the impedance module registered for the lowest frequency (0.1 Hz) was noted for the TNT sample and, what is essential, the |Z| value was precisely the same for both immobilization times, which proves the complete saturation of the TNT layer only after 0.5 h of the protein deposition. Similar to TNTs, comparable changes in impedance parameters for both immobilization times are recorded for the 10sd_AgNPs/TNT electrode, which is why it was considered that half an hour is sufficient to saturate this platform.…”
Section: Resultsmentioning
confidence: 99%
“…5(a). As can be seen, at the bare ions bearing negative charge and deaccelerate the diffusion process of redox probe to the GCE surface [62]. Compared to curve b, an obvious expansion in the capacity of the anodic and cathodic currents was observed when the rGO was casted on GCE/GO (curve c) due to its good conductivity and large active surface area of rGO.…”
Section: Electrochemical Behavior Of the Hbsag Aptasensormentioning
confidence: 91%
“… 102 Several research teams have made great efforts to detect lymphoma and MM based on the electrochemical biosensors. 76 79 , 87 …”
Section: Applications Of Electrochemical Biosensors In Lymphoma and MMmentioning
confidence: 99%
“…Moreover, Geetha et al 78 developed a novel electrochemical immunosensor for FR detection, adopting FA-modified RGO nanosheets as the substrate. Through the covalent immobilization of HSP70 antibodies on GO as a bio-recognition element, Ozcan and Sezginturk 79 proposed a label-free immunosensor to analyze HSP70 via electrochemical methods such as CV and AC impedance. All of these sensors used for the detection of biomolecules related to lymphoma or MM have achieved relatively satisfactory results, suggesting their great potentiality in the early evaluation of tumor diseases.…”
Section: Applications Of Electrochemical Biosensors In Lymphoma and MMmentioning
confidence: 99%