2005
DOI: 10.1016/j.nima.2004.11.025
|View full text |Cite
|
Sign up to set email alerts
|

GRAPES-3—A high-density air shower array for studies on the structure in the cosmic-ray energy spectrum near the knee

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
67
0

Year Published

2009
2009
2015
2015

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 98 publications
(76 citation statements)
references
References 20 publications
0
67
0
Order By: Relevance
“…Belov et al (2001) and Kane (2010) maintain that there is a reasonable correlation between the FD magnitude and the product of maximum magnetic field and maximum solar wind velocity. Dumbović et al (2012) also found reasonable correlation A&A 580, A41 (2015) detectors (each 1 m 2 ), with a distance of 8 m between adjacent detectors deployed in a hexagonal geometry (Gupta et al 2005;Mohanty et al 2009;Mohanty et al 2012). The GRAPES-3 array is designed to measure the energy spectrum and composition of the primary cosmic rays in the energy region from 10 TeV to 100 PeV (Gupta et al 2009;Tanaka et al 2012).…”
Section: Introductionmentioning
confidence: 83%
“…Belov et al (2001) and Kane (2010) maintain that there is a reasonable correlation between the FD magnitude and the product of maximum magnetic field and maximum solar wind velocity. Dumbović et al (2012) also found reasonable correlation A&A 580, A41 (2015) detectors (each 1 m 2 ), with a distance of 8 m between adjacent detectors deployed in a hexagonal geometry (Gupta et al 2005;Mohanty et al 2009;Mohanty et al 2012). The GRAPES-3 array is designed to measure the energy spectrum and composition of the primary cosmic rays in the energy region from 10 TeV to 100 PeV (Gupta et al 2009;Tanaka et al 2012).…”
Section: Introductionmentioning
confidence: 83%
“…The GRAPES-3 (Gamma Ray Astronomy at PeV EnergieS Phase-3) extensive air shower (EAS) array [60] has been designed to have one of the most compact configurations of the conventional type arrays with only 8 m separation between adjacent detectors that are arranged in a symmetric hexagonal geometry. The final target is to have 15 rings with 721 detectors, covering a distance up to 120 m from the center of the array, the observations were started in 2000 with 217 detectors located within the inner 8 rings.…”
Section: The Initial Arraymentioning
confidence: 99%
“…Most of these muons pass through the detector located above the muon telescope, thus providing the distribution of the integrated-charge for the passage of minimum ionizing particles. Typical single particle response for a detector in terms of the distribution of integrated-charge (ADC value) follows the Landau distribution [60]. The most probable ADC value obtained from the calibration distribution for each detector is used to convert the signal observed in a shower to 'equivalent' number of particles.…”
Section: S K Guptamentioning
confidence: 99%
See 2 more Smart Citations