2021
DOI: 10.1007/978-1-0716-1024-4_2
|View full text |Cite
|
Sign up to set email alerts
|

Good Old-Fashioned Protein Concentration Determination by Amino Acid Analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
2
1

Relationship

3
3

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 4 publications
0
7
0
Order By: Relevance
“…CSF datasets we generated used four digestion strategies, including standard in-solution digestion, rapid in-solution digestion, standard filter-aided sample preparation (FASP), and rapid FASP, assuming different sample preparations result in different peptide recovery after digestion, leading to variations at the peptide and protein levels. To ensure that the same amount of peptides was analyzed using MS for all the samples, amino acid analysis (AAA) [ 44 ] had been performed for peptide quantification. The peptide quantification results already confirmed that the different digestion methods vary in sample recovery.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…CSF datasets we generated used four digestion strategies, including standard in-solution digestion, rapid in-solution digestion, standard filter-aided sample preparation (FASP), and rapid FASP, assuming different sample preparations result in different peptide recovery after digestion, leading to variations at the peptide and protein levels. To ensure that the same amount of peptides was analyzed using MS for all the samples, amino acid analysis (AAA) [ 44 ] had been performed for peptide quantification. The peptide quantification results already confirmed that the different digestion methods vary in sample recovery.…”
Section: Resultsmentioning
confidence: 99%
“…The peptide concentration in the digested samples was determined by amino acid analysis (AAA) as described by Plum [ 43 ] and May et al [ 44 ]. According to AAA, 500 ng per sample was taken for nanoLC-MS analysis and analyzed as previously described [ 43 , 44 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…For amino acid analysis, each sample was dried completely in a glass tube. Subsequent amino acid analysis was performed using the Acquity HPLC and AccQ-Tag Ultra system (Waters GmbH) as previously described (20).…”
Section: Methodsmentioning
confidence: 99%
“…Samples were dried in a vacuum concentrator and resuspended in 40 µl 0.1% (v/v) TFA. Afterwards, the peptide concentration was determined by amino acid analysis (AAA) as described previously 31 .…”
Section: Mass Spectrometry For the Identification Of Atad1 Interactio...mentioning
confidence: 99%