2016
DOI: 10.18203/2320-6012.ijrms20163547
|View full text |Cite
|
Sign up to set email alerts
|

Goldmann applanation tonometry versus non-contact tonometry: a comparative study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

3
1
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 9 publications
3
1
1
Order By: Relevance
“…For IOP <10 mmHg it varied by 1-2 mmHg and for >24 mmHg the range was in between 2-5 mmHg. The overestimation of IOP in lower range was also noted by Chakrabarty L. 22 The mean CCT of right eye was 528.9± 29.6micron meters and that of left eye was 530.6±29.6micron meters. All the four instruments namely GAT, Perkin's, Icare ic100 and NCT were influenced by CCT but values positively correlated for Icare ic100 (r 2 =0.032) and NCT (r 2 = 0.035).…”
Section: Discussionsupporting
confidence: 53%
See 2 more Smart Citations
“…For IOP <10 mmHg it varied by 1-2 mmHg and for >24 mmHg the range was in between 2-5 mmHg. The overestimation of IOP in lower range was also noted by Chakrabarty L. 22 The mean CCT of right eye was 528.9± 29.6micron meters and that of left eye was 530.6±29.6micron meters. All the four instruments namely GAT, Perkin's, Icare ic100 and NCT were influenced by CCT but values positively correlated for Icare ic100 (r 2 =0.032) and NCT (r 2 = 0.035).…”
Section: Discussionsupporting
confidence: 53%
“…Most studies showed NCT overestimates IOP in higher range and underestimates at lower range. [21][22][23] In our study, NCT overestimated IOP in either extremes. For IOP <10 mmHg it varied by 1-2 mmHg and for >24 mmHg the range was in between 2-5 mmHg.…”
Section: Discussioncontrasting
confidence: 42%
See 1 more Smart Citation
“…Contrary to some studies, good correlation between GAT and NCT in higher IOP ranges was found. 3 In our study we found NCT values were significantly higher than that of GAT and the values were statistically significant. Shih et al had an objective to ascertain whether CCT affected patient management.…”
Section: Discussionsupporting
confidence: 49%
“…Contrary to some studies, good correlation between GAT and NCT in higher IOP ranges was found. 6 In our study we found that NCT values are higher compared to GAT values. NCT overestimates IOP more when CCT values are more than 560-micron metre.…”
Section: Discussionsupporting
confidence: 44%