2020
DOI: 10.1016/j.memsci.2020.117822
|View full text |Cite
|
Sign up to set email alerts
|

Gold nanoparticle mixture retention test with single particle detection: A fast and sensitive probe for functional pore sizes of ultrafiltration membranes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
7
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 44 publications
2
7
0
Order By: Relevance
“…Therefore, the filtration time was optimized for 2 min to determine the selectivity of the membrane. This is compatible with the duration used in the previous methods which were based on a short time filtration experiment for the determination of the membrane pore size [ 34 ]. This time (2 min) is a compromise between having a sufficient volume of permeate for Nanosight analysis and having a minimum of fouling, in order to limit its impact on the determination of the MWCO.…”
Section: Resultssupporting
confidence: 64%
See 3 more Smart Citations
“…Therefore, the filtration time was optimized for 2 min to determine the selectivity of the membrane. This is compatible with the duration used in the previous methods which were based on a short time filtration experiment for the determination of the membrane pore size [ 34 ]. This time (2 min) is a compromise between having a sufficient volume of permeate for Nanosight analysis and having a minimum of fouling, in order to limit its impact on the determination of the MWCO.…”
Section: Resultssupporting
confidence: 64%
“…Thus, for each NP size tested, the determination of MWCO is affected by the smallest NPs which are blocked in the membrane. So we can deduce that the larger the chosen size, the closer we get to a satisfactory determination of the MWCO as evidenced by the agreement with the manufacturer’s data and a study in the literature [ 34 ]. The same conclusion is obtained for the membrane M2, where the MWCO of the membrane was estimated at 85, 121.5 and 181.5 nm from the retention curves of NPs100-200-300, respectively.…”
Section: Resultssupporting
confidence: 58%
See 2 more Smart Citations
“…The technique was assessed as especially favorable for the fast and sensitive probe for functional pore sizes of ultraltration membranes by investigating the retention of NPs. 398 3.3.6.2. LA-ICP-MS.…”
Section: Methodology and Applicationsmentioning
confidence: 99%