2021
DOI: 10.1007/s00604-020-04642-8
|View full text |Cite
|
Sign up to set email alerts
|

Glutathione and cystamine functionalized MoS2core-shell nanoparticles for enhanced electrochemical detection of doxorubicin

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(5 citation statements)
references
References 33 publications
0
5
0
Order By: Relevance
“…A schematic representation of a three-electrode system setup toward the target analyte is displayed in Figure a. Electrochemical impedance spectroscopy (EIS) capacities are conducted to provide the charge transfer resistance ( R ct ) of modified GCEs with respect to the bare electrode in 0.1 M KCl containing 5 mM [Fe­(CN) 6 ] 3–/4– , which reveals variability in R ct values attributed to surface modification. As observed in Figure b, the Nyquist plot of LaV/h-BN/GCE exhibits a smaller R ct value of 81.19 Ω·cm 2 as compared to a bare GCE (426.72 Ω·cm 2 ), LaV (275.04 Ω·cm 2 ), and h-BN (128.51 Ω·cm 2 ) modified electrodes. A smaller R ct value entails more facetious electron transfer kinetics signifying superior electrocatalytic activity for the LaV/h-BN/GCE composite.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…A schematic representation of a three-electrode system setup toward the target analyte is displayed in Figure a. Electrochemical impedance spectroscopy (EIS) capacities are conducted to provide the charge transfer resistance ( R ct ) of modified GCEs with respect to the bare electrode in 0.1 M KCl containing 5 mM [Fe­(CN) 6 ] 3–/4– , which reveals variability in R ct values attributed to surface modification. As observed in Figure b, the Nyquist plot of LaV/h-BN/GCE exhibits a smaller R ct value of 81.19 Ω·cm 2 as compared to a bare GCE (426.72 Ω·cm 2 ), LaV (275.04 Ω·cm 2 ), and h-BN (128.51 Ω·cm 2 ) modified electrodes. A smaller R ct value entails more facetious electron transfer kinetics signifying superior electrocatalytic activity for the LaV/h-BN/GCE composite.…”
Section: Resultsmentioning
confidence: 99%
“…The direct relationship is validated by the calibration curve in Figure b with the regression correlation coefficient ( R 2 ) of 0.991. The proposed sensor shows confirmations of remarkable electrocatalytic activity with the attainment of values as low as a detection limit of 0.5 nM and wide linear responses of 0.001–89 μM, and values are calculated using the standard formula The evaluation of the analytical features of the LaV/h-BN-based electrochemical platform (Table ) signifies its efficient performance compared to those of previously reported studies, where, from the i – t curve, it is obtained to be 5 s on average for each and every addition of the analyte. The improved performance of the sensor can be recognized in accordance with the synergistic interactions between LaV and h-BN, the creation of electroactive edge sites, better electronic conductivity, and morphological encapsulation supporting electron transfer.…”
Section: Resultsmentioning
confidence: 99%
“…Its mechanism of action involves inhibiting DNA replication and transcription in cancer cells [ 4 , 5 ]. However, DOX has several adverse effects on the human body, including nausea, vomiting, liver failure, local tissue necrosis, and potential heart failure [ 6 , 7 ]. Therefore, it is crucial to closely monitor the dosage of DOX in human biological fluids and further regulate its concentration.…”
Section: Introductionmentioning
confidence: 99%
“…In recent years, many methods have been developed for the detection of DOX, such as high-performance liquid chromatography mass spectrometry (HPLC-MS), [6] mass spectrometry (MS), [7] capillary electrophoresis (CE) [8] and electrochemical methods. [9,10] Although these techniques have produces good performances for DOX analysis, there is still the need for increased effort to develop a sensitive, quick responding and inexpensive strategy for monitoring DOX in plasma.…”
Section: Introductionmentioning
confidence: 99%